5-2 Setting⑥: Setting Number of Output Channel
Address
Register name
6054h
OutputCh_Select R/W
5-2-8 Setting Number of Output Channel
[Function]
Setting number of output channel (connector)
Also check p.32 and p.33 of this document to setting this
parameter.
(1ch Output)
Image data is outputted from max. 6 connectors
(D1,D2,D5,D6,D9,D10) ) if using Medium, Full, Deca Config.
Image data is outputted from max. 3 connectors(D1,D5,D9) if
using Base Config.
This output method is called "1ch output". This method is the
standard output mode in ordinary operation and ex-factory
condition.
( 2ch Output )
Image data is outputted from max. 12 connectors (D1-D12) if
using Medium, Full, Deca Config.
Image data is outputted from max .6 connectors
(D1,D3,D5,D7,D9,D11) if using Base Config.
Above output method is called "2ch output".
TM-XJ959A
R/W
Parameter
Data
Setting number of output channel
0 to 1
0: Output from Ch1 only (1Ch Output)
1: Output from Ch1 and Ch2 (2Ch Output)
Camera Link® is a trade mark registered by AIA(Automated Imaging Association).
Function
【Remark】
1) When changing OutputCh_Select, this is reflected
including slave channel.
2)
Because "Setting Number of Output Channel"
interacts with Line Frequency and number of output pixel,
please set this setting based on your calculation for each
setting.
Initial
0