5-2 Setting ① Select Baud rate

5-2-1 Communication Speed setting

【 Input 】
Command Parameter End code
BR
**
CR
[initial setting]
9.6kbps
[Selectable setting]
9.6kbps
19.2kbps
115.2kbps
Parameter
00
01
02
Example
Select Baud rate to 115.2kbaud .
BR 02 <CR>
TM-XG537C
Baud rate
9.6kbaud
19.2kbaud
115.2kbaud
COPYRIGHT © 2020 MITSUBISHI ELECTRIC CORPORATION. ALL RIGHTS RESERVED.
【 UART Serial Communication speed setting 】
[Function]
This command sets a baud rate of Serial communication ,
UART , from 3 type of speed .
Initial Baud rate is 9.6kbaud .
【 Remarks 】
1) For communication speed to change just after CR of a
command line "CR" was sent, there is no answer output.