3-3 Connections
3-3-2 DC5V cable connection
(This cable is not included in the CIS product)
1)Connect ① DC5V power cable to CIS connectors V1/V3(for
L4) or V1/V2/V3(for L5/L6).
Type
No.
Power for
V1
CIS(+5V)
V2
V3
2) Fix CIS connectors and the cable by screws
CIS has locknut D20418-J3R (JAE) (M2.6, female).
Use M2.6 screw, M2.5 screw, M2.6 type JAE Lock screw,
etc., which are applicable to fix cable connectors.
Recommended screwing torque is 16 - 20 N*cm.
TM-XJ959A
Model
L4
L5
L6
×
【Remarks】
1) Do not screw with higher torque than recommended.
Otherwise, locknut on CIS may be loosened or removed
when you remove screws.
2) CIS does not support hot-swap.
Make sure to power off CIS before connecting / removing
cables. If the cables are connected / removed while
powered on, it may cause failure on CIS.