5-2 Setting⑧: Sync Signal Setting
Address
Register name
6028h TriggerMode
7000h LinePeriodCounter
5-2-10 Sync Signal Setting
[Function]
Select a Sync Signal input source.
Select External Sync mode and provide sync signals to
CIS, when your object transport speed is changeable. (For
more details, please refer to Chapter 4-3.)
Select Internal Sync mode and control line frequency, when
your object transport speed is fixed. You can change line
frequency max. 1,872 usec/line.
TM-XJ959A
R/W
Parameter
Data
Set Sync Signal input source
R/W
0 or 1
0: Internal Sync mode
1: External Sync mode
0
Set Line Frequency (Internal Sync mode)
R/W
To
65535
Function
Line Frequency = ܿ݁ ݏݑ
[Remark]
1) In the external synchronization mode, input a line
synchronization signal with a reading frequency that
matches the medium to be read or the CIS transport
speed.
Initial
0
ܴ݁݃݅ 1 + ݁ݑ ݈ܽݒ ݎ݁ ݐݏ
35
5833
75