Mitsubishi Electric KD Series User Manual page 52

Contact image sensor, web surface inspection
Hide thumbs Also See for KD Series:
Table of Contents

Advertisement

3-2 Preparation
3-2-1 Preparation by users
⑦External illumination control cable
This product outputs a trigger signal from connector L1,
that is used to synchronize the exposure timing of this
product with an external illumination. When using this
trigger signal for the external illumination control, prepare
the cable to connect with the external illumination.
Cable with following connectors are recommended.
Housing:
DEU-9P-F0R (JAE)
Contact pin:
030-50641 (JAE)
CIS connector has DEU-9S-F0R (JAE),
Contact socket has 030-50640 (JAE).
Pin assignment of CIS connectors is shown below.
Pin
Name
No
1
2
NC
3
4
OUT PULSE1
5
6
NC
7
8
OUT PULSE2
9
GND
TM-XJ959A
I/O
Remarks
-
O
3.3V LVTTL
-
O
3.3V LVTTL
O
【Reference】
Illumination trigger signal timing chart
External sync
signal
Latency
Internal sync
signal
Off
Illumination (LED)
pulse signal
Line frequency
*N= number of divisions
52
© Mitsubishi Electric Corporation