3-3 Connections
3-3-3 Camera Link® connectors
(This cable is not included in the CIS product)
1)Connect Camera Link® cable to D1-D8(for L4/L5) or D1-D12(for L6).
* CIS has Mini-Camera Link® connectors 12226-1150-00PL(3M).
【L4/L5】
【L6】
【Remarks】
1)When you use several Grabber boards, the external sync signal
can be provided only through Master Communication port
(L4/L5:D1,L6:D5). Also communication control for the main functions
can be set only through Master Communication port.
(L4/L5:D1,L6:D5) Remark when changing Grabber board settings.
2)CIS does not support PoCL. Set the Frame Grabber board settings
NOT to supply +12V power over the Camera Link® cable.
3)Pin assignment of the Camera Link® connectors are conformed to
Camera Link® standard.
4) Recommended screwing torque is 12 N*cm.
TM-XJ959A
Camera Link® is a registered trademark of AIA (Automated Imaging Association).
Type
Camera Link® Connectors
*◎: Master Communication port
© Mitsubishi Electric Corporation
No.
Model
L4
L5
L6
D1
D2
D3
D4
D5
D6
D7
D8
×
×
D9
×
×
D10
×
×
D11
×
×
D12