Functions, monitoring and protective functions
9.3 Drive functions
Note
List of exceptions with activated know-how protection
A list of the adjustable parameters which, in spite of activated know-how protection, can be
changed, is provided in the List Manual.
The list has the designation "KHP_WRITE_NO_LOCK".
Functions that cannot be executed when know-how protection is active
The following functions cannot be executed when know-how protection is active:
● Download
● Automatic controller adjustment
● Stationary/rotating measurement
● Clearing fault buffer
● Creating acceptance documentation
Functions which can be executed as an option when know-how protection is active
The functions listed below can be executed with activated know-how protection provided
diagnostic functions were permitted when it was activated:
● Trace function
● Function generator
● Measuring functions
Adjustable parameters that are read-only when know-how protection is active
The following adjustable parameters can be read but not changed when know-how
protection is active:
● Motor parameters (p0100, p0300, p0304, p0305, p0349)
● Data sets (p0120, p0130, p0140, p0150, p0170, p0180)
● Encoder type (p0400)
● Reference values (p2000, p2001, p2002, p2003, p2005, p2006, and p2007)
These parameters are grayed out in the STARTER in the expert list.