6.6.7.3
CCW/CW selection
Settings: Menu – Commissioning/Service – AOP Settings – Control Settings
CCW/CW selection (factory setting: No)
● Yes: Switching between CW/CCW rotation by means of the CW/CCW key possible in
LOCAL mode
● No: The CW/CCW key has no effect in LOCAL mode
For safety reasons, the CW/CCW key is disabled in the factory setting (pumps and fans must
normally only be operated in one direction).
In the "Operation" status in LOCAL mode, the current direction of rotation is indicated by an
arrow next to the operating state.
Note
You have to make additional settings when switching between CW/CCW rotation.
6.6.7.4
Jog
Settings: Menu – Commissioning/Service – AOP Settings – Control Settings
JOG key active (factory setting: No)
● Yes: The JOG key functions in LOCAL mode in the "Ready for power up" status (not in
"Operation enabled" status). The speed that is set in parameter p1058 is approached.
● No: The JOG key has no effect in LOCAL mode
6.6.7.5
Increase setpoint / decrease setpoint
You can use the Increase and Decrease keys to enter the setpoint with a resolution of 1 % of
the maximum speed.
Alternatively, the setpoint can also be entered via the numeric keys. To do so, press F2 in
the operation screen. The system displays an editing field for entering the required speed.
Enter the required value using the numeric keypad. Press F5 "OK" to confirm the setpoint.
Using the number keys, any speed ranging between the maximum speed (p1080) and
minimum speed (p1082) can be entered.
Converter cabinet units
Operating Instructions, 11/2017, A5E36652151A
6.6 Control via the operator panel
Operation
307