Unexpected motor movement during motor identification in the rotating mode
When selecting motor identification with optimization in the rotating mode, after
commissioning, the drive initiates that the motor rotates with speeds that can reach the
maximum motor speed.
• Observe the general safety instructions.
• Ensure that the EMERGENCY STOP functions are fully functional when commissioning
Note
Activate enable signals
Make sure that the necessary enable signals have been assigned; otherwise motor
identification cannot be carried out.
Note
Fault with stationary or rotating measurements
The motor identification cannot be performed if, when selecting the stationary or rotating
measurement, a fault is active
Before rectifying the fault, you have to choose "No identification" and close the screen.
Motor identification can then be selected again via <MENU> - <Commissioning/service> -
<Drive commissioning> - <Motor identification>.
Converter cabinet units
Operating Instructions, 11/2017, A5E36652151A
WARNING
the drive.
5.5 Initial commissioning with the AOP30