Siemens SINAMICS S150 NEMA Operating Instructions Manual page 306

Converter cabinet units 15hp-1250hp
Hide thumbs Also See for SINAMICS S150 NEMA:
Table of Contents

Advertisement

Operation
6.6 Control via the operator panel
Keyboard test
In this screen, you can check that the keys are functioning properly. Keys that you press are
represented on a symbolic keyboard on the display. You can press keys in any order you
wish. You cannot exit the screen (F4 – "Back") until you have pressed each key at least
once.
Note
Exit keyboard test
Alternatively, you can exit the keyboard test screen by pressing any key and holding it down.
Screenshots
A screenshot is created by simultaneously pressing keys "1" and "+/-" - and then the display
flashes 2 times, one after the other. A maximum of 8 screenshots can be managed.
The list of the saved screenshots is displayed in the "Screenshots" menu item.
The screenshot is selected from the list and is displayed by pressing F5.
While the screenshot is being displayed, the identifier and the time stamp are displayed
flashing in the title line every 5 seconds.
By pressing any function key F1 ... F5, the function key assignment is displayed for 5
seconds.
● The display is exited by pressing F4 and the list of screenshots is redisplayed.
● By pressing the F5 key once and then pressing F5 "Clear" again to confirm, the displayed
screenshot will be deleted and the list of screenshots will be displayed again.
To clear all of the screenshots, in the list of screenshots, press F5 for longer than 1 second -
and confirm the following prompt with "Yes".
If there are gaps in the list of screenshots, then they are populated with new screenshots
from the top to the bottom. When the list is full, then the oldest chronological entry in the list
is overwritten.
Note
Battery buffering
The screenshots are saved to the memory, buffered by a battery - and are also available
after the power supply has been switched-off and switched-on again.
When the AOP30 is switched off and the battery is too weak - or when changing the
batteries - a buffer time of approximately 30 minutes applies.
LED test
In this screen, you can check that the four LEDs are functioning properly.
304
Converter cabinet units
Operating Instructions, 11/2017, A5E36652151A

Advertisement

Table of Contents
loading

Table of Contents