Upper: Input the signal input value for the upper limit
Lower: Input the signal input value for the lower limit.
Unit: The unit specified in Scaling is displayed.
Pre-trigger: Specify the effective range of the data before the trigger level as a percentage.
Trigger 0%
Trigger level
20%
Trigger 20%
The effective data is from the 20% of data prior to the trigger up to the 100% point.
Combination: Combination: Four combinations of setting conditions can be selected.
OR: The trigger is activated when any one of the specified conditions is met.
AND: The trigger is activated when all of the specified conditions are met.
• Stop Trigger
Source: Specify the stop condition for the capture of event data.
Off: Click the Stop key to stop data capture.
Amp: Data capture is stopped when the Edge condition is satisfied.
Note: See the CHECKPOINT on page 3-24 for more details on the Edge conditions.
Ext.: Data capture is stopped when a signal is input from an external trigger terminal.
CH: Select Analog, Logic, or Pulse channels.
A, B: Analog channels
Logic: Logic channels
Pulse: Pulse channels
CHECKPOINT
Logic and Pulse cannot be selected at the same. Select either Logic or Pulse.
Function: Specify the Trigger Stop condition.
A, B: Off: The Trigger function is disabled.
Hi: The trigger is activated when the signal input rises to (or exceeds) the specified
trigger level.
Lo: The trigger is activated when the signal input falls to (or goes below) the
specified trigger level.
Win In:
The trigger is activated when the signal input goes within (or is within) both
limits
Win Out: The trigger is activated when the signal input goes outside (or is outside)
both limits.
Logic: Off: Triggering is not performed.
Hi: The trigger is activated when the Logic signal rises to the Hi level.
Lo: The trigger is activated when the Logic signal falls to the Lo level.
Pulse: Off: Triggering is not performed.
Hi: The trigger is activated when the Pulse signal rises to the Hi level.
Lo: The trigger is activated when the Pulse signal falls to the Lo level.
Upper: Input the signal input value for the upper limit.
Lower: Input the signal input value for the lower limit.
Unit: The unit specified in Scaling is displayed.
Combination: Four combinations of setting conditions can be selected.
OR: The trigger is activated when any one of the specified conditions is met.
AND: The trigger is activated when all of the specified conditions are met.