Transport, storage and packaging
3.2.
Storage
Long-term storage
3.3.
Packaging
14
SA 25.1
SA 48.1/SAR 25.1
Weights for multi-turn actuators SA 25.1
with 3-phase AC motors
Type designation
Actuator
SA 35.1
SA 40.1
SA 48.1
1)
Refer to motor name plate
2)
Indicated weight includes AUMA NORM multi-turn actuator with 3-phase AC motor, electrical con-
nection in standard version, output drive type B1 and handwheel. For other output drive types, heed
additional weights.
Table 6:
Weights for output drive type A 25.2
Type designation
A 25.2
A 30.2
A 35.2
A 40.2
Danger of corrosion due to inappropriate storage!
Store in a well-ventilated, dry room.
Protect against floor dampness by storage on a shelf or on a wooden pallet.
Cover to protect against dust and dirt.
Apply suitable corrosion protection agent to uncoated surfaces.
Damage on display caused by temperatures below permissible level!
AC actuator controls MUST NOT be stored below 30 °C.
For long-term storage (more than 6 months), observe the following points:
1.
Prior to storage:
Protect uncoated surfaces, in particular the output drive parts and mounting
surface, with long-term corrosion protection agent.
2.
At an interval of approx. 6 months:
Check for corrosion. If first signs of corrosion show, apply new corrosion protec-
tion.
Our products are protected by special packaging for transport when leaving the
factory. The packaging consists of environmentally friendly materials which can easily
be separated and recycled. We use the following packaging materials: wood,
cardboard, paper, and PE foil. For the disposal of the packaging material, we
recommend recycling and collection centres.
SAR 30.1 Control unit: electronic (MWG)
AC 01.2 Non-Intrusive Modbus RTU
SA 48.1 / SAR 25.1
1)
Motor type
AD... 132-...
AD... 160-...
AD... 160-...
AD... 180-...
A 40.2
Flange size
F 25.2
F 30.2
F 35.2
F 40.2
SAR 30.1
2)
Weight
approx. [kg]
410
425
510
750
[kg]
42
69
126
202