AUMA SA 48.1 Operation Instructions Manual
AUMA SA 48.1 Operation Instructions Manual

AUMA SA 48.1 Operation Instructions Manual

Electric multi-turn actuators. auma norm for flanges type fa

Advertisement

Quick Links

Electric multi-turn actuators
SA 07.1 – SA 48.1
SAR 07.1 – SAR 30.1
AUMA NORM
for flanges type FA
Operation instructions

Advertisement

Table of Contents
loading

Summary of Contents for AUMA SA 48.1

  • Page 1 Electric multi-turn actuators SA 07.1 – SA 48.1 SAR 07.1 – SAR 30.1 AUMA NORM for flanges type FA Operation instructions...
  • Page 2: Table Of Contents

    Scope of these instructions: These instructions are valid for multi-turn actuators of the type range SA 07.1 – SA 48.1 and SAR 07.1 – SAR 30.1 in version AUMA NORM. These operation instructions are only valid for “clockwise closing”, i.e. driven shaft turns clockwise to close the valve.
  • Page 3 Maintenance Lubrication Disposal and recycling Service Spare parts list Multi-turn actuator SA(R) 07.1 – SA(R) 16.1 with plug/socket connector Spare parts list Multi-turn actuator SA 25.1 – SA 48.1/SAR 25.1 – SAR 30.1 Index Addresses of AUMA offices and representatives...
  • Page 4: Safety Instructions

    Short description AUMA multi-turn actuators type SA 07.1 – SA 48.1 and SAR 07.1 – SAR 30.1 have a modular design. The limitation of travel is realized via limit switches in both end positions.
  • Page 5: Technical Data

    Table 1: Multi-turn actuator SA 07.1 – SA 48.1 /SAR 07.1 – SAR 30.1 Multi-turn actuators AUMA NORM require electric controls. AUMA offers the controls AUMA MATIC AM or AUMATIC AC for the sizes SA(R) 07.1 - SA(R) 16.1. These can also easily be mounted to the actuator at a later date.
  • Page 6 Multi-turn actuators SA 07.1 – SA 48.1 / SAR 07.1 – SAR 30.1 AUMA NORM Operation instructions Service conditions Output drive types A, B1, B2, B3, B4 according ISO 5210 (A, B2, B4 according to MSS SP-102) A, B, D, E according to DIN 3210...
  • Page 7: Transport, Storage And Packaging

    Multi-turn actuators SA 07.1 – SA 48.1 / SAR 07.1 – SAR 30.1 Operation instructions AUMA NORM Transport, storage and packaging Transport For transport to place of installation, use sturdy packaging. Do not attach ropes or hooks to the handwheel for the purpose of lifting by hoist.
  • Page 8: Mounting To Valve/Gearbox

    Multi-turn actuators SA 07.1 – SA 48.1 / SAR 07.1 – SAR 30.1 AUMA NORM Operation instructions We use the following packaging materials: wood, cardboard, paper and Polyurethane foam. For the disposal of the packaging material, we recommend recycling and collection centers.
  • Page 9 Multi-turn actuators SA 07.1 – SA 48.1 / SAR 07.1 – SAR 30.1 Operation instructions AUMA NORM Finish machining of stem nut (output drive type A): Figure B-1 Output drive type A Stem nut 80.3 80.01/80.02 80.2 The output drive flange does not have to be removed from the actuator.
  • Page 10: Manual Operation

    Multi-turn actuators SA 07.1 – SA 48.1 / SAR 07.1 – SAR 30.1 AUMA NORM Operation instructions Manual operation The actuator may be operated manually for purposes of setting and commissioning, and in case of motor failure or power failure.
  • Page 11: Electrical Connection

    Multi-turn actuators SA 07.1 – SA 48.1 / SAR 07.1 – SAR 30.1 Operation instructions AUMA NORM Electrical connection Work on the electrical system or equipment must only be carried out by a skilled electrician themselves or by specially instructed personnel under the control and supervision of such an electrician and in accordance with the applicable electrical engineering rules.
  • Page 12: Motor Connection For The Sizes Sa(R) 25.1/Sar 30.1 - Sa

    Multi-turn actuators SA 07.1 – SA 48.1 / SAR 07.1 – SAR 30.1 AUMA NORM Operation instructions Motor connection for the sizes SA(R) 25.1/SAR 30.1 – SA 48.1. From the size SA(R) 25.1, the power for the motor is connected to separate terminals.
  • Page 13: Limit And Torque Switches

    Multi-turn actuators SA 07.1 – SA 48.1 / SAR 07.1 – SAR 30.1 Operation instructions AUMA NORM Limit and torque switches Only the same potential can be switched on the two circuits (NC/NO contact) of a Figure G-5 limit or torque switch. If different potentials are to be switched simultaneously, tandem switches are required.
  • Page 14: Opening The Switch Compartment

    Multi-turn actuators SA 07.1 – SA 48.1 / SAR 07.1 – SAR 30.1 AUMA NORM Operation instructions Opening the switch To be able to carry out the following settings (sections 9. to 15.), the switch compartment compartment must be opened and, if installed, the indicator disc must be removed.
  • Page 15: Setting The Limit Switching

    Multi-turn actuators SA 07.1 – SA 48.1 / SAR 07.1 – SAR 30.1 Operation instructions AUMA NORM Setting the limit switching Setting the end position CLOSED (black section) Turn handwheel clockwise until valve is closed. After having reached the end position, turn back handwheel by approximately ½...
  • Page 16: Setting The Duo Limit Switching (Option)

    Multi-turn actuators SA 07.1 – SA 48.1 / SAR 07.1 – SAR 30.1 AUMA NORM Operation instructions 10. Setting the DUO limit switching (option) Any application can be switched on or off via the two intermediate position switches. For setting, the switching point (intermediate position) must be approached from the same direction as later during electrical operation.
  • Page 17: Setting The Torque Switching

    Multi-turn actuators SA 07.1 – SA 48.1 / SAR 07.1 – SAR 30.1 Operation instructions AUMA NORM 11. Setting the torque switching 11.1 Setting The set torque must suit the valve! This setting should only be changed with the consent of the...
  • Page 18: Test Run

    Multi-turn actuators SA 07.1 – SA 48.1 / SAR 07.1 – SAR 30.1 AUMA NORM Operation instructions 12. Test run 12.1 Check direction of rotation If provided, place indicator disc on shaft. The direction of rotation of the indicator disc (figure M-1) indicates the direction of rotation of the output drive.
  • Page 19: Setting The Potentiometer (Option)

    Multi-turn actuators SA 07.1 – SA 48.1 / SAR 07.1 – SAR 30.1 Operation instructions AUMA NORM 13. Setting the potentiometer (option) – For remote indication – Move valve to end position CLOSED. If installed, pull off indicator disc. Turn potentiometer (E2) clockwise until stop is felt.
  • Page 20: Setting The Electronic Position Transmitter Rwg (Option)

    Multi-turn actuators SA 07.1 – SA 48.1 / SAR 07.1 – SAR 30.1 AUMA NORM Operation instructions 14. Setting the electronic position transmitter RWG (option) – For remote indication or external controls – After mounting the multi-turn actuator to the valve, check setting by measuring the output current (see sections 14.1 or 14.2) and re-adjust, if necessary.
  • Page 21: Setting For 2-Wire System 4 - 20 Ma And 3-/4-Wire System 0 - 20 Ma

    Multi-turn actuators SA 07.1 – SA 48.1 / SAR 07.1 – SAR 30.1 Operation instructions AUMA NORM 14.1 Setting for 2-wire system 4 – 20 mA and 3-/4-wire system 0 – 20 mA Connect voltage to electronic position transmitter. Move valve to end position CLOSED.
  • Page 22: Setting The 3-/4- Wire System 4 - 20 Ma

    Multi-turn actuators SA 07.1 – SA 48.1 / SAR 07.1 – SAR 30.1 AUMA NORM Operation instructions 14.2 Setting the 3-/4- wire system 4 – 20 mA Connect voltage to electronic position transmitter. Move valve to end position CLOSED. If installed, pull off indicator disc.
  • Page 23 Multi-turn actuators SA 07.1 – SA 48.1 / SAR 07.1 – SAR 30.1 Operation instructions AUMA NORM 15. Setting the mechanical position indicator (option) Place indicator disc on shaft. Move valve to end position CLOSED. Turn lower indicator disc (figure Q1) until symbol CLOSED is in alignment with the mark on the cover (figure Q-2).
  • Page 24 Multi-turn actuators SA 07.1 – SA 48.1 / SAR 07.1 – SAR 30.1 AUMA NORM Operation instructions 17. Enclosure protection IP 68 (option) Definition According to EN 60 259, the conditions for meeting the requirements of enclosure protection IP 68 are to be agreed between manufacturer and user.
  • Page 25 Multi-turn actuators SA 07.1 – SA 48.1 / SAR 07.1 – SAR 30.1 Operation instructions AUMA NORM 18. Maintenance After maintenance, check multi-turn actuator for damage to paint finish. If damage to paint-finish has occurred, it has to be touched up to avoid corrosion. Original paint in small quantities can be supplied by AUMA.
  • Page 26 Multi-turn actuators SA 07.1 – SA 48.1 / SAR 07.1 – SAR 30.1 AUMA NORM Operation instructions 20. Disposal and recycling AUMA actuators have an extremely long lifetime. However, they have to be replaced at one point in time. The actuators have a modular design and may therefore easily be disassembled, separated, and sorted according to materials, i.e.:...
  • Page 27 Multi-turn actuators SA 07.1 – SA 48.1 / SAR 07.1 – SAR 30.1 Operation instructions AUMA NORM 22. Spare parts list Multi-turn actuator SA(R) 07.1 – SA(R) 16.1 with plug/socket connector...
  • Page 28 Multi-turn actuators SA 07.1 – SA 48.1 / SAR 07.1 – SAR 30.1 AUMA NORM Operation instructions Notes: When placing orders for spare parts, it is essential to mention type of actuator and our commission number (refer to actuator name plate). Delivered spare parts may slightly vary from the representation in these instructions.
  • Page 29 Multi-turn actuators SA 07.1 – SA 48.1 / SAR 07.1 – SAR 30.1 Operation instructions AUMA NORM 23. Spare parts list Multi-turn actuator SA 25.1 – SA 48.1/SAR 25.1 – SAR 30.1...
  • Page 30 Multi-turn actuators SA 07.1 – SA 48.1 / SAR 07.1 – SAR 30.1 AUMA NORM Operation instructions Notes: When placing orders for spare parts, it is essential to mention type of actuator and our commission number (refer to actuator name plate). Delivered spare parts may slightly vary from the representation in these instructions.
  • Page 31 Multi-turn actuators SA 07.1 – SA 48.1 / SAR 07.1 – SAR 30.1 Operation instructions AUMA NORM Index Corrosion protection Maintenance Tandem switches Manual operation Technical data Mechanical position indicator Test run DUO limit switching Motor protection Thermoswitches Mounting to valve/gearbox...
  • Page 32 North American Sales and Service: International Headquarters: AUMA Riester GmbH & Co. KG US Headquarters and Factory: Müllheim/ Germany AUMA Actuators, Inc. www.auma.com 100 Southpointe Blvd. International Sales and Service: Canonsburg PA 15317 Tel: 724-743-AUMA (2862) South America: Fax: 724-743-4711 Argentina email: mailbox@auma-usa.com...

This manual is also suitable for:

Sa 07.1Sar 07.1Sar 30.1Sa 48.1 sar 07.1

Table of Contents