Table of Contents
2
Safety Instructions
6
Basic Information on Safety
6
Range of Application
6
Applications in Ex Zone 22 (Option)
7
Warnings and Notes
7
References and Symbols
8
Identification
9
Short Description
9
Name Plate
10
Transport, Storage and Packaging
14
Transport
14
Storage
15
Packaging
15
Assembly
17
Mounting Position
17
Handwheel Fitting
17
Multi-Turn Actuator: Mount to Valve/Gearbox
18
Output Drive Type a
18
4.3.1.1. Stem Nut: Finish Machining
19
4.3.1.2. Multi-Turn Actuator (with Output Drive Type A): Mount to Valve
20
Output Drive Types B and E
21
4.3.2.1. Multi-Turn Actuator with Output Drive Types B: Mount to Valve/Gearbox
21
Accessories for Assembly
22
Stem Protection Tube for Rising Valve Stem
22
Mounting Positions of Local Controls
23
Mounting Positions: Modify
24
Electrical Connection
25
Basic Information
25
Electrical Connection of Actuator Controls
27
S/SH/SD Electrical Connection (AUMA Plug/Socket Connector)
27
5.2.1.1. Terminal Compartment (for Mains Connection): Open
28
5.2.1.2. Cable Connection
29
5.2.1.3. Terminal Compartment (for Mains Connection): Close
31
HART Terminal Compartment: Open (Version with HART Connection Board)
32
5.2.1.5. HART Cables: Connect
33
HART Terminal Compartment: Close (Version with HART Connection Board)
35
Electrical Connection of Actuator
35
Motor Connection
36
5.3.1.1. Motor Connection Compartment: Open
36
5.3.1.2. Motor Cables: Connect
37
5.3.1.3. Motor Connection Compartment: Close
38
S/SH Electrical Connection (AUMA Plug Socket Connector)
39
5.3.2.1. Terminal Compartment: Open
39
5.3.2.2. Cable Connection
40
5.3.2.3. Terminal Compartment: Close
41
Accessories for Electrical Connection
42
Actuator Controls on Wall Bracket
42
Connection with Control Box
43
Parking Frame
45
DS Intermediate Frame for Double Sealing
45
External Earth Connection
46
Operation
47
Manual Operation
47
Engage Manual Operation
47
Manual Operation: Disengage
48
Motor Operation
48
Local Actuator Operation
48
Actuator Operation from Remote
49
Menu Navigation Via Push Buttons (for Settings and Indications)
49
Menu Layout and Navigation
50
User Level, Password
51
Password Entry
52
Password Change
52
Language in the Display
53
Language Change
53
Indications
55
Indications During Commissioning
55
Indications in the Display
55
Feedback Indications from Actuator and Valve
56
Status Indications According to AUMA Classification
58
Status Indications According to NAMUR Recommendation
59
Indication Lights of Local Controls
61
Optional Indications
62
Mechanical Position Indication Via Indicator Mark
62
Signals (Output Signals)
63
Signals Via HART
63
Status Signals Via Output Contacts (Digital Outputs)
63
Assignment of Outputs
63
Coding the Outputs
63
Analogue Signals (Analogue Outputs)
63
Commissioning (Basic Settings)
65
Type of Seating: Set
65
HART Address (Slave Address): Set
66
Switch Compartment: Open
67
Torque Switching: Set
67
Limit Switching: Set
68
End Position CLOSED (Black Section): Set
68
End Position OPEN (White Section): Set
69
Intermediate Positions: Set
69
Running Direction CLOSE (Black Section): Set
70
Running Direction OPEN (White Section): Set
70
Test Run
70
Direction of Rotation at Mechanical Position Indicator: Check
70
Direction of Rotation at Hollow Shaft/Stem: Check
71
Limit Switching: Check
72
Reference Operation Position Feedback: Perform
72
Commissioning (Optional Equipment Settings)
73
EWG 01.1 Electronic Position Transmitter
73
Measuring Range: Set
74
Current Values : Adjust
74
LED End Position Signalling: Switch On/Off
75
Potentiometer
75
Potentiometer: Set
75
RWG Electronic Position Transmitter
76
Measuring Range: Set
76
Mechanical Position Indicator: Set
77
Switch Compartment: Close
77
Corrective Action
79
Faults During Commissioning
79
Fault Indications and Warning Indications
79
Fuses
83
Fuses Within the Actuator Controls
83
Fuse Replacement
84
Replace Fuses
84
Test/Replace Fuses
85
Motor Protection (Thermal Monitoring)
85
Servicing and Maintenance
86
Preventive Measures for Servicing and Safe Operation
86
Maintenance
87
Disposal and Recycling
87
Technical Data
88
Technical Data Multi-Turn Actuators
88
Technical Data Actuator Controls
91
Spare Parts
98
Multi-Turn Actuators SA
98
Sa 48.1/Sar 25.1
98
AC 01.2 Actuator Controls with S Electrical Connection
100
AC 01.2 Actuator Controls with SD Electrical Connection
102
Wall Bracket
104
Certificates
106
EU Declaration of Incorporation / Declaration of Conformity
106
Index
107
Addresses
110
Advertisement
AUMA SAR 30.1 Operating Instructions Manual (104 pages)
Multi-turn actuators, Control unit: electronic MWG with actuator controls, Non-Intrusive
Brand:
AUMA
| Category:
Controller
| Size: 3.4 MB
Table of Contents
Table of Contents
2
1 Safety Instructions
5
Basic Information on Safety
5
Range of Application
5
Applications in Ex Zone 22 (Option)
6
Warnings and Notes
7
References and Symbols
7
2 Identification
8
Short Description
8
Name Plate
9
3 Transport, Storage and Packaging
13
Transport
13
Storage
14
Packaging
14
4 Assembly
15
Mounting Position
15
Handwheel Fitting
15
Multi-Turn Actuator: Mount to Valve/Gearbox
16
Output Drive Type a
16
Stem Nut: Finish Machining
17
Multi-Turn Actuator (with Output Drive Type A): Mount to Valve
18
Output Drive Types B and E
19
Multi-Turn Actuator with Output Drive Types B: Mount to Valve/Gearbox
19
Accessories for Assembly
20
Stem Protection Tube for Rising Valve Stem
20
Mounting Positions of Local Controls
21
Mounting Positions: Modify
22
5 Electrical Connection
23
Basic Information
23
Electrical Connection of Actuator Controls
26
SD Electrical Connection (AUMA Plug/Socket Connector)
26
Terminal Compartment (for Mains Connection): Open
27
Cable Connection
28
Terminal Compartment (for Mains Connection): Close
29
Fieldbus Terminal Compartment: Open
30
Fieldbus Cables: Connect
31
Fieldbus Terminal Compartment: Close
32
Electrical Connection of Actuator
33
Motor Connection
34
Motor Connection Compartment: Open
34
Motor Cables: Connect
34
Motor Connection Compartment: Close
35
S/SH Electrical Connection (AUMA Plug Socket Connector)
36
Terminal Compartment: Open
36
Cable Connection
37
Terminal Compartment: Close
38
Accessories for Electrical Connection
39
Actuator Controls on Wall Bracket
39
Connection with Control Box
40
Parking Frame
42
DS Intermediate Frame for Double Sealing
42
External Earth Connection
43
Operation
44
Manual Operation
44
Engage Manual Operation
44
Manual Operation: Disengage
45
Motor Operation
45
Local Actuator Operation
45
Actuator Operation from Remote
46
Menu Navigation Via Push Buttons (for Settings and Indications)
46
Menu Layout and Navigation
47
User Level, Password
48
Password Entry
49
Password Change
49
Language in the Display
50
Language Change
50
Indications
52
Indications During Commissioning
52
Indications in the Display
52
Feedback Indications from Actuator and Valve
53
Status Indications According to AUMA Classification
55
Status Indications According to NAMUR Recommendation
56
Indication Lights of Local Controls
58
Optional Indications
59
Mechanical Position Indication (Self-Adjusting)
59
Mechanical Position Indication Via Indicator Mark
59
Signals (Output Signals)
60
Status Signals Via Output Contacts (Digital Outputs)
60
Assignment of Outputs
60
Coding the Outputs
60
Analogue Signals (Analogue Outputs)
60
Commissioning (Basic Settings)
61
Type of Seating: Set
61
Torque Switching: Set
62
Limit Switching: Set
63
Fieldbus Address (Slave Address), Baud Rate, Parity and Monitoring Time: Set
65
Test Run
66
Direction of Rotation at Mechanical Position Indicator: Check
66
Direction of Rotation at Hollow Shaft/Stem: Check
67
Limit Switching: Check
68
Commissioning (Settings/Options in the Actuator)
69
Switch Compartment: Open/Close
69
Mechanical Position Indicator (Self-Adjusting)
70
Mechanical Position Indicator: Set
70
Gear Stage of the Reduction Gearing: Test/Set
71
Mechanical Position Indication Via Indicator Mark (Not Self-Adjusting)
72
Mechanical Position Indicator: Set
72
Gear Stage of the Reduction Gearing: Test/Set
73
Corrective Action
75
Faults During Commissioning
75
Fault Indications and Warning Indications
75
Fuses
79
Fuses Within the Actuator Controls
79
Fuse Replacement
80
Replace Fuses F1/F2
80
Test/Replace Fuses
80
Motor Protection (Thermal Monitoring)
81
Servicing and Maintenance
82
Preventive Measures for Servicing and Safe Operation
82
Maintenance
83
Disposal and Recycling
83
Technical Data
84
Technical Data Multi-Turn Actuators
84
Technical Data Actuator Controls
86
Spare Parts
92
Multi-Turn Actuators SA
92
Sa 48.1/Sar 25.1
92
AC 01.2 Actuator Controls with SD Electrical Connection
94
Wall Bracket
96
Certificates
98
EU Declaration of Incorporation / Declaration of Conformity
98
Index
99
Addresses
102
AUMA SAR 30.1 Operation Instructions Manual (92 pages)
Multi-turn actuators
Brand:
AUMA
| Category:
Controller
| Size: 2.87 MB
Table of Contents
Table of Contents
2
Safety Instructions
5
Basic Information on Safety
5
Range of Application
5
Warnings and Notes
6
References and Symbols
6
Identification
8
Name Plate
8
Short Description
11
Transport, Storage and Packaging
12
Transport
12
Storage
13
Packaging
13
Assembly
14
Mounting Position
14
Handwheel Fitting
14
Multi-Turn Actuator: Mount to Valve/Gearbox
15
Output Drive Type a
15
4.3.1.1. Stem Nut: Finish Machining
16
4.3.1.2. Multi-Turn Actuator (with Output Drive Type A): Mount to Valve
17
Output Drive Types B and E
18
4.3.2.1. Multi-Turn Actuator with Output Drive Types B: Mount to Valve/Gearbox
18
Accessories for Assembly
19
Stem Protection Tube for Rising Valve Stem
19
Electrical Connection
21
Basic Information
21
Connection with Control Box
23
Electrical Connection of Actuator Controls
24
Electrical Connection S/SH (AUMA Plug/Socket Connector)
24
5.3.1.1. Terminal Compartment : Open
25
5.3.1.2. Cable Connection
26
5.3.1.3. Terminal Compartment : Close
27
Electrical Connection of Actuator
28
Motor Connection
29
5.4.1.1. Motor Connection Compartment: Open
29
5.4.1.2. Motor Cables: Connect
29
5.4.1.3. Motor Connection Compartment: Close
30
S/SH Electrical Connection (AUMA Plug/Socket Connector)
31
5.4.2.1. Terminal Compartment: Open
31
5.4.2.2. Cable Connection
32
5.4.2.3. Terminal Compartment: Close
33
Accessories for Electrical Connection
34
Actuator Controls on Wall Bracket
34
Parking Frame
35
DS Intermediate Frame for Double Sealing
36
External Earth Connection
36
Operation
37
Manual Operation
37
Engage Manual Operation
37
Manual Operation: Disengage
38
Motor Operation
38
Local Operation
38
Actuator Operation from Remote
39
Indications
40
Indication Lights
40
Optional Indications
40
Mechanical Position Indication Via Indicator Mark
40
Signals (Output Signals)
42
Feedback Signals Via Output Contacts (Binary)
42
Feedback Signals (Analogue)
42
Commissioning (Basic Settings)
43
Heat-Up Time for Low Temperature Version
43
Switch Compartment: Open
43
Torque Switching: Set
44
Limit Switching: Set
44
End Position CLOSED (Black Section): Set
45
End Position OPEN (White Section): Set
45
Test Run
46
Direction of Rotation at Mechanical Position Indicator: Check
46
Direction of Rotation at Hollow Shaft/Stem: Check
46
Limit Switching: Check
47
Switch Compartment: Close
47
Commissioning (Optional Equipment Settings)
49
Potentiometer
49
Potentiometer: Set
49
RWG Electronic Position Transmitter
49
Measuring Range: Set
50
EWG 01.1 Electronic Position Transmitter
50
Measuring Range: Set
51
Current Values : Adjust
52
LED End Position Signalling: Switch On/Off
53
Intermediate Positions: Set
53
Running Direction CLOSE (Black Section): Set
54
Running Direction OPEN (White Section): Set
54
Mechanical Position Indicator: Set
54
Commissioning Controls Settings
56
Actuator Controls: Open
56
Type of Seating: Set
56
Push-To-Run Operation or Self-Retaining: Set
57
Running Indication (Blinker Transmitter): Activate/Deactivate
58
Torque Fault in Collective Fault Signal: Activate/Deactivate
58
Leds for Torque Fault, Phase Failure, Motor Protection
58
Positioner
59
Input Ranges (Signal Type) for Setpoint and Actual Value
59
Behaviour on Loss of Signal (Actuator Reaction)
60
Adjustment in End Positions
61
Sensitivity Setting
63
EMERGENCY Command (EMERGENCY - OPEN/EMERGENCY - CLOSE)
64
Actuator Controls: Close
64
PTC Tripping Device (Option): Test
65
Corrective Action
66
Faults During Commissioning
66
Fuses
66
Fuses Within the Actuator Controls
66
Fuses Within the Control Box
68
Motor Protection (Thermal Monitoring)
69
Servicing and Maintenance
70
Preventive Measures for Servicing and Safe Operation
70
Maintenance
71
Disposal and Recycling
71
Technical Data
72
Technical Data Multi-Turn Actuators
72
Technical Data Actuator Controls
74
Technical Data Control Box
77
Spare Parts
79
Multi-Turn Actuators SA
79
Sa 48.1/Sar 25.1
79
Actuator Controls am 01.1/AM
81
Wall Bracket
83
Control Cabinet for Switchgear
85
Certificates
87
EU Declaration of Incorporation / Declaration of Conformity
87
Index
88
Addresses
90
Advertisement
AUMA SAR 30.1 Operation Instructions Manual (60 pages)
Multi-turn actuators
Brand:
AUMA
| Category:
Controller
| Size: 2.53 MB
Table of Contents
Table of Contents
2
Safety Instructions
4
Prerequisites for the Safe Handling of the Product
4
Range of Application
4
Warnings and Notes
5
References and Symbols
5
Short Description
7
Name Plate
8
Transport and Storage
10
Transport
10
Storage
11
Assembly
12
Mounting Position
12
Fit Handwheel
12
Mount Actuator to Valve
13
Overview of Output Drive Types
13
Output Drive Type a
14
Output Drive Types B/C/D/E
18
Accessories for Assembly
19
Stem Protection Tube for Rising Valve Stem
19
Electrical Connection
21
Basic Information
21
Motor Connection
22
Open Motor Connection Compartment
23
Connect Motor Cables
24
Close Motor Connection Compartment
25
S/SH Electrical Connection (AUMA Plug/Socket Connector)
25
Open Terminal Compartment
26
Cable Connection
27
Close Terminal Compartment
28
Accessories for Electrical Connection (Option)
29
Parking Frame
29
DS Intermediate Frame for Double Sealing
29
External Earth Connection
30
Operation
31
Manual Operation
31
Manual Valve Operation
31
Motor Operation
32
Indications (Option)
33
Mechanical Position Indication Via Indicator Mark
33
Signals (Output Signals)
34
Feedback Signals from Actuator
34
Commissioning (Basic Settings)
35
Open Switch Compartment
35
Set Torque Switching
35
Set Limit Switching
36
Set End Position CLOSED (Black Section)
36
Set End Position OPEN (White Section)
37
Test Run
37
Check Direction of Rotation at Mechanical Position Indicator
37
Check Direction of Rotation at Hollow Shaft/Stem
38
Check Limit Switching
39
Close Switch Compartment
39
Commissioning (Optional Equipment Settings)
40
Potentiometer
40
Potentiometer Setting
40
RWG Electronic Position Transmitter
40
Set Measuring Range
41
EWG 01.1 Electronic Position Transmitter
41
Set Measuring Range
42
Adjust Current Values
43
Switch On/Off LED End Position Signalling
44
Set Intermediate Positions
44
Set Running Direction CLOSE (Black Section)
45
Set Running Direction OPEN (White Section)
45
Set Mechanical Position Indicator
45
Corrective Actions
47
Faults During Operation/Commissioning
47
Motor Protection (Thermal Monitoring)
48
Servicing and Maintenance
49
Preventive Measures for Servicing and Safe Operation
49
Maintenance
50
Disposal and Recycling
50
Technical Data
51
Technical Data Multi-Turn Actuators
51
Tightening Torques for Screws
53
Spare Parts List
54
Multi-Turn Actuators SA 25.1 - SA 48.1 S / SAR 25.1 - SAR 30.1 S
54
Index
56
AUMA SAR 30.1 Operation Instructions Manual (48 pages)
Multi-turn actuators, AUMA NORM (without controls)
Brand:
AUMA
| Category:
Controller
| Size: 1.26 MB
Table of Contents
Table of Contents
2
Safety Instructions
4
Basic Information on Safety
4
Range of Application
4
Applications in Ex Zone 22 (Option)
5
Warnings and Notes
5
References and Symbols
6
Identification
7
Name Plate
7
Short Description
7
Transport, Storage and Packaging
8
Transport
8
Storage
8
Packaging
8
Assembly
9
Mounting Position
9
Handwheel Fitting
9
Multi-Turn Actuator: Mount to Valve/Gearbox
10
Output Drive Types B, B1
10
B4 and E
10
Multi-Turn Actuator
10
B4 or E): Mount to Valve/Gearbox
10
Output Drive Type a
11
Stem Nut: Finish Machining
11
Multi-Turn Actuator (with Output Drive Type A): Mount to Valve
12
Accessories for Assembly
13
Stem Protection Tube for Rising Valve Stem
13
Electrical Connection
14
Basic Information
14
Motor Connection
15
Connection with AUMA Plug/Socket Connector
16
Terminal Compartment: Open
17
Cable Connection
17
Terminal Compartment: Close
19
Accessories for Electrical Connection
19
Parking Frame
19
Protection Cover
20
Double Sealed Intermediate Frame
20
Earth Connection, External
20
Operation
21
Manual Operation
21
Manual Operation: Engage
21
Manual Operation: Disengage
21
Motor Operation
22
Indications
23
Mechanical Position Indicator/Running Indication
23
Signals
24
Feedback Signals from Actuator
24
Commissioning
25
Switch Compartment: Open
25
Torque Switching: Set
25
Limit Switching: Set
26
End Position CLOSED (Black Section): Set
26
End Position OPEN (White Section): Set
27
Intermediate Positions: Set
27
Running Direction CLOSE (Black Section): Set
28
Running Direction OPEN (White Section): Set
28
Test Run
28
Direction of Rotation: Check
28
Limit Switching: Check
29
Potentiometer Setting
30
Electronic Position Transmitter RWG: Set
30
Mechanical Position Indicator: Set
31
Switch Compartment: Close
32
Corrective Action
33
Faults During Commissioning
33
Motor Protection (Thermal Monitoring)
33
Maintenance
34
Preventive Measures for Servicing and Safe Operation
34
Servicing and Maintenance
34
Disposal and Recycling
35
Features and Functions of Actuator
36
Technical Data
36
Further Information
38
Service Conditions
38
Multi-Turn Actuators SA
39
Sa 48.1/Sar 25.1
39
Spare Parts
39
Certificates
41
Declaration of Incorporation and EC Declaration of Conformity
41
Index
44
Addresses
46
AUMA SAR 30.1 Operation Instructions Manual (32 pages)
Electric multi-turn actuators. AUMA NORM for flanges type FA
Brand:
AUMA
| Category:
Controller
| Size: 1.94 MB
Table of Contents
Table of Contents
2
1 Safety Instructions
4
Commissioning (Electrical Connection)
4
Maintenance
4
Range of Application
4
2 Short Description
4
Warnings and Notes
4
3 Technical Data
5
Packaging
7
Storage
7
Transport
7
4 Transport, Storage and Packaging
7
5 Mounting to Valve/Gearbox
8
6 Manual Operation
10
Connection with AUMA Plug/Socket Connector
11
7 Electrical Connection
11
Controls Made by AUMA
12
Delay Time
12
Heater
12
Motor Connection for Special Motors
12
Motor Connection for the Sizes SA(R) 25.1/SAR 30.1 - SA
12
Motor Protection
12
Remote Position Transmitter
12
Fitting of the Cover
13
Limit and Torque Switches
13
8 Opening the Switch Compartment
14
Pulling off the Indicator Disc (Option)
14
Removing the Switch Compartment Cover
14
Checking the Limit Switches
15
Setting the End Position CLOSED (Black Section)
15
Setting the End Position OPEN (White Section)
15
9 Setting the Limit Switching
15
Checking the DUO Switches
16
Setting the Direction CLOSE (Black Section)
16
Setting the Direction OPEN (White Section)
16
10 Setting the DUO Limit Switching (Option)
16
Checking the Torque Switches
17
Setting
17
11 Setting the Torque Switching
17
Check Direction of Rotation
18
Check Limit Switching
18
12 Test Run
18
13 Setting the Potentiometer (Option)
19
14 Setting the Electronic Position Transmitter RWG (Option)
20
Setting for 2-Wire System 4 - 20 Ma and 3-/4-Wire System 0 - 20 Ma
21
Setting the 3-/4- Wire System 4 - 20 Ma
22
Advertisement
Related Products
AUMA SAR 30
AUMA SAR3-SAR100
AUMA SAR3
AUMA SAR 30.1-UW
AUMA SAR 12
AUMA SAR 25
AUMA SAR 10.2
AUMA SARN 14.1
AUMA SARVE 10.2 Series
AUMA SAR 14.1
AUMA Categories
Controller
Industrial Equipment
Control Unit
Control Systems
Outboard Motor
More AUMA Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL