Technical data

13.
Technical data
Information
13.1.

Technical data Multi-turn actuators

Features and functions
Type of duty
(Multi-turn actuators for open-close
duty)
Type of duty
(Multi-turn actuators for modulating
duty)
Motors
Mains voltage, mains frequency
Overvoltage category
Insulation class
Motor protection
Self-locking
Motor heater (option)
Manual operation
Valve attachment
84
SA 25.1
SA 48.1/SAR 25.1
The following tables include standard and optional features. For detailed information
on the customer-specific version, refer to the order-related data sheet. The technical
data sheet can be downloaded from the Internet in both German and English at ht-
tp://www.auma.com (please state the order number).
Standard:
Short-time duty S2 - 15 min, classes A and B according to EN 15714-2
Option:
With 3-phase AC motor:
Short-time duty S2 - 30 min, classes A and B according to EN 15714-2
For nominal voltage and +40 °C ambient temperature and at load with 35 % of the max. torque.
Standard:
Intermittent duty S4 - 25 %, class C according to EN 15714-2
Option:
With 3-phase AC motor:
Intermittent duty S4 - 50 %, class C according to EN 15714-2
Intermittent duty S5 - 25 % (insulation class H required), class C according to EN 15714-
2
For nominal voltage and +40 °C ambient temperature and at modulating torque load.
3-phase asynchronous motor
type IM B9 according to IEC 60034-7, IC410 cooling procedure according to IEC 60034-6
Refer to motor name plate
Permissible variation of mains voltage: ±10 %
Permissible variation of mains frequency: ±5 %
Category III according to IEC 60364-4-443
Standard:
F, tropicalized
Option:
H, tropicalized
Standard:
Thermoswitches (NC)
Option:
PTC thermistors (according to DIN 44082)
PTC thermistors additionally require a suitable tripping device in the actuator controls.
Self-locking: Speeds up to 90 rpm (50 Hz) or 108 rpm (60 Hz) and from size SA 35.1 for output speeds
up to 22 rpm (50 Hz) or 26 (60 Hz)
NOT self-locking: SA 25.1 and SA 30.1 for output speeds from 125 rpm (50Hz) or 150 rpm (60Hz) and
from size SA 35.1 for output speeds from 32 rpm (50Hz) or 38 (60Hz).
Multi-turn actuators are self-locking, if the valve position cannot be changed from standstill while torque
acts upon the output drive.
Voltages:
110
120 V AC, 220
Power depending on the size 12.5
Manual drive for setting and emergency operation, handwheel does not rotate during electrical operation
Option:
Handwheel lockable
Handwheel stem extension
Power tool for emergency operation with square 30 mm or 50 mm
Standard:
B1 according to EN ISO 5210
Options:
A, B2, B3, B4, C, D nach EN ISO 5210
A, B, D, E according to DIN 3210
C according to DIN 3338
Special valve attachments: AF, AK, AG, B3D, ED, DD (IB1 or IB3 for size 25.1 only, largest sizes on
request)
A prepared for permanent lubrication of stem
SAR 30.1 Control unit: electronic (MWG)
AC 01.2 Non-Intrusive Modbus RTU
240 V AC or 380
480 V AC
25 W