Removing The High-Pressure Pump - Bosch DCI 700 Repair Instructions

Common-rail injector test bench
Hide thumbs Also See for DCI 700:
Table of Contents

Advertisement

5.1.5

Removing the high-pressure pump

1
2
3
4
5
6
 30:
Removing the pump plate
1. Remove hex nut (1) and lock washer (2). Insert a 10 mm round rod into the hole in the pump drive plate and
hold the pump drive plate securely while loosening the hex. head bolt.
 31:
Loosening the hex nut
2. Screw the two hex. head bolts (M10 x 1 x 35 mm) with washers that were removed when disassembling the
drive coupling into the two holes in the pump drive plate and push the pump drive plate off the drive shaft of the
high-pressure pump.
3. Remove the pump drive plate from the drive shaft of the high-pressure pump.
4. Remove the 3 hex. head bolts (4) and washers. The hex. head bolts are secured with threadlocker.
5. Remove the pump plate (5) from the high-pressure pump (6).
---
Robert Bosch GmbH
DCI 700 | 23 | en
1 689 975 289 | 2020-05-06