Attaching The Pump Plate - Bosch DCI 700 Repair Instructions

Common-rail injector test bench
Hide thumbs Also See for DCI 700:
Table of Contents

Advertisement

 33:
Attaching the pump drive plate
10. Remove all sealing plugs from the high-pressure pump.
---
5.1.7

Attaching the pump plate

1. Check whether the thrust rings (1) have been tightened on both pressure lines (left-hand thread). Remove the
adapter nuts and turn the thrust rings counterclockwise as far as possible. Reinstall the adapter nuts.
1
 34:
Checking the thrust ring
2. Place the pump plate (2) on the rotating frame (3). The spring pins (4) of the pump plate must be inserted into
the spring pin holes in the rotating frame.
3. Secure the pump plate with 4 Torx screws (1) and washers. Do not tighten the Torx screws (1).
Robert Bosch GmbH
458929-41_Pal
DCI 700 | 25 | en
1 689 975 289 | 2020-05-06