Opening The Dci 700 Help Center; Tools And Aids Needed; Protective Clothing And Equipment; Cleanliness Requirements - Bosch DCI 700 Repair Instructions

Common-rail injector test bench
Hide thumbs Also See for DCI 700:
Table of Contents

Advertisement

• 1 689 979 860 – Important information and safety instructions for Bosch Diesel Test Equipment
• Service information 200108_084 – Information regarding DGUV regulation 3 for electrical systems and equipment
• DCI 700 Help Center
---Separator---
1.6

Opening the DCI 700 Help Center

1. In the "DCI" software, select <?>.
2. Select the "Help Center" tab.
The link takes you to the DCI 700 Help Center:
---Separator---
1.7

Tools and aids needed

• General tools for mechanics and electricians
• 60 mm wrench
• Torque wrench with range of 10 – 50 Nm
• Torque wrench with range of 4 – 18 Nm
• PC/laptop
• Multimeter
• Reference pressure sensor 1 681 032 095
• Adapter nut 1 683 345 064 (M16 – M20)
• Adapter nut 1 683 345 070 (M16 – M18)
• Adapter 1 681 398 035 (M16 – M16)
• USB stick
• Mounting device 0 986 617 285 for adjusting the drive coupling
• Mounting device 1 687 012 187 for installing and removing the drive motor
• 2x Rectangular wooden strips (59 x 5 x 350 mm) for removing the mounting panel
• Test oil collecting container (with no leaks)
• Round rod Ø10 x 150 mm
• Threadlocker, e.g. Loctite 243
• Datalogic D9530-HP hand scanner. The Datalogic D9530-HP hand scanner is also used for Bosch QualityScan.
• USB extension cable (3 m) 1 684 465 565
• Cloths for catching and wiping up test oil
• Lint-free paper towels
• Cleaned containers with a cover. The containers are needed to hold the components removed during repair and
prevent their contamination.
---Separator---
1.8

Protective clothing and equipment

• Protective gloves
• Safety goggles
• Safety shoes
---Separator---
1.9

Cleanliness requirements

Exceptional cleanliness is required during repair and as soon as the measuring circuit or high-pressure circuit has
been opened. The smallest particles can damage the tester and test specimen. To prevent this, the following meas‐
ures must be implemented and observed when performing repairs.
• Always perform repairs in a clean environment with clean air.
• When performing repairs, make sure no other work is in progress which could emit particles into the air. If the
requirements cannot be met, perform repairs at a clean workspace with an extraction device.
• Clean up the workplace before performing repairs.
• Clean the workplace and tools with lint-free paper towels.
• Always keep and transport the components removed in clean containers with a cover.
• Do not leave measurement blocks and flow meters open.
• Do not blow out the measuring circuit and high-pressure circuit with compressed air.
---