en | 34 | DCI 700
1
2
 49:
Quantity measurement block with fan assembly
12. Connect both connection cables from the fan assembly to connection cables M6 and M7.
---
5.2.6

Entering the calibration values

1. Switch on the DCI 700 at the main switch.
2. Start the DCI software.
3. If a mouse is not connected, connect a mouse to an unused USB port of the processor unit,
4. Connect hand scanner to an unused USB port on the processor unit by means of a 3 m USB extension cable
1 684 465 565.
5. Open the notepad.
6. Cover the CR code (1) on the flow meter.
7. Using the hand scanner, scan the QR code (2).
1
2
 50:
Reading the QR code
 After the QR code has been scanned, the serial number, order number and calibration points with the calibra‐
tion values of the flow meter appear on the notepad.
— Alternatively, a smartphone with a QR code app can be used to scan the QR code on the flow meter. The cali‐
bration values must then be transferred to the DCI software manually.
8. In the DCI software, select "Calibration >> Quantity".
9. In the selection list at the left, select the channel on which the flow meter has been replaced (e.g. injector quan‐
tity B T12).
1 689 975 289 | 2020-05-06