Bosch DCI 700 Repair Instructions page 31

Common-rail injector test bench
Hide thumbs Also See for DCI 700:
Table of Contents

Advertisement

1
2
 43:
Quantity measurement block with fan assembly
4. Remove the connection cable (2) from the flow meter (1).
1
2
 44:
Flow meter with connection cable
5. Remove both fastening screws.
6. Remove the flow meter (1) and both O-rings from the spacer plate (2).
Do not clean the surface of the spacer plate (2) with a cloth or the like, or blow off with compressed air (risk
of contamination). Particles can stick to the surface during cleaning and find their way into the flow meter
during operation.
Robert Bosch GmbH
DCI 700 | 31 | en
1 689 975 289 | 2020-05-06