28 | FSA 500 | Technical data
8.
Technical data
8.1
Dimensions and weights
Property
Dimensions (W x H x D)
Weight (without accessories)
8.2
Specifications
Property
Rated voltage U(V)
Rated power P(W)
Degree of protection
8.3
Temperature, humidity and atmos-
pheric pressure
8.3.1
Ambient temperature
Property
Storage and transportation
Function
Measuring accuracy
Storage battery charging tempe-
rature
8.3.2
Humidity
Property
Storage and transportation
Function
Measuring accuracy
8.3.3
Air pressure
Property
Storage and transportation
Operation (at 25 °C and 24 h)
Measuring accuracy
8.4
Noise emissions
< 70 dB(A)
8.5
Power supply unit
Property
Frequency
Input voltage (AC)
Input current
Output voltage (DC)
Output current
|
1 689 989 411
2019-04-01
Value/range
200 x 280 x 110 mm
7.9 x 11.0 x 4.3 inch
1,5 kg
3.3 lb
Value/range
19 DC
60
IP 30
Value/range
5 °C – 40 °C
41 °F – 104 °F
5 °C – 40 °C
41 °F – 104 °F
10 °C – 35 °C
50 °F – 95 °F
0 - 45 °C
Value/range
30 % – 60 %
20 % – 80 %
30 % – 60 %
Value/range
700 hPa – 1060 hPa
700 hPa – 1060 hPa
700 hPa – 1060 hPa
Value/range
50 – 60 Hz
100 – 240 V~
1,8 A
19 V
3,4 A
8.6
Storage battery
Property
Storage battery life
Charging time for storage-battery ca-
pacity > 70%
(with empty storage battery and FSA
500 switched off; charging time in-
creases with parallel measurements)
8.7
RED (Radio Equipment Directive)
Wireless link
Frequency band
Bluetooth
2,4 GHz
8.8
Bluetooth Class 1 and 2
Wireless link Class 1 (100 mW)
Free field workshop environment
For measurements in vehicle engine
compartment
Wireless link Class 2 (10 mW)
Free field workshop environment
For measurements in vehicle engine
compartment
8.9
Signal generator
Function
Amplitude
Signal forms
Frequency range
Output voltage max.
Impedance
Symmetry
Curve generation
Short-circuit proof with respect
to interference voltage, static
Short-circuit proof with respect
to interference voltage, dynamic
Additionally:
R
Automatically engaged filters and damping members
to improve signal quality.
R
Automatic shut-off in the case of short circuit,
detection of interference voltage on starting signal
generator.
Value/range
< 4 h
< 1 h
Maximum radiated trans-
mitter power output
19,9 dBm
Minimum range
30 m
10 m
Minimum range
3 m
1 m
Specification
- 10 V – 12 V
(load < 10 mA) to
ground
DC, sinusoidal, triangular,
square-wave
1 Hz – 1 kHz
75 mA
approx. 60 Ohm
10 % – 90 %
(triangular, square-wave)
Output rate up to 100000
values/s,
resolution 8 bit,
Y full range adjustable
(bit),
unipolar / bipolar opera-
tion
< 50 V
< 500 V / 1 ms
Robert Bosch GmbH