Installing Circuit Board A3 - Bosch DCI 700 Repair Instructions

Common-rail injector test bench
Hide thumbs Also See for DCI 700:
Table of Contents

Advertisement

 75:
Removing circuit board A3
---
5.4.6

Installing circuit board A3

Take note of the ESD handling instructions in EDIS, and remove components with care.
Extreme bending may damage the circuit board.
When installing the circuit board, take care not to slide it across a sheet metal edge of the test bench. This
may cause components on the circuit board to get detached or damaged.
Circuit board A3 is always provided in conjunction with circuit board A4. Do not separate the circuit boards.
---
1. Remove circuit board A3 from the packaging along with the ESD protection.
2. Check if the slotted-in circuit board A4 is correctly attached to circuit board A3.
A4
A3
 76:
Circuit board A3 with circuit board A4
3. Carefully, place circuit board A3 on the spacers and clip it in.
4. Use 2 oval-head screws and washers to secure circuit board A3.
Robert Bosch GmbH
1
2
DCI 700 | 49 | en
1 689 975 289 | 2020-05-06