Bosch DCI 700 Repair Instructions page 43

Common-rail injector test bench
Hide thumbs Also See for DCI 700:
Table of Contents

Advertisement

1
2 4
 65:
Fastening the mounting panel
6. Use 2 Torx screws M6 x 16 mm and washers to secure cover (1) to the mounting panel.
 66:
Fastening the cover
7. Use Torx screws M6 x 16 mm (3 and 5) and washers to secure protective cover (4). While attaching it, make sure
the protective conductor is connected to the cover.
8. Use Torx screws M6 x 16 mm (2) to secure cover (1).
Robert Bosch GmbH
458929-49_Pal
3
2
1
2
458929-50_Pal
DCI 700 | 43 | en
1 689 975 289 | 2020-05-06