5.1.2

Removing the cover for motor compartment and electrical compartment

1. Close the protective door.
2. Using a square box wrench, open both electrical cabinet locks
the scope of delivery of the DCI 700.
3. Lift cover (2), pull to the right and remove.
— If necessary, remove the protective conductor on the inside of the cover.
1.
 25:
Removing the cover
5.1.3
---

Removing the protective doors

Voraussetzungen:
Before removing the protective door, disconnect the DCI 700 at the main switch
tion.
---
1. Open the protective door (3). The door contact
for door monitoring (1).
1 2
3
 26:
Preparing to replace the protective cover
2. With the aid of another person, lift and remove the protective door.
1 689 975 289 | 2020-05-06
1
2.
2
3
(2)
for the safety switch must be located outside the switch box
4
and 3). The square box wrench is included in
(1
(4)
and secure against reactiva‐
Robert Bosch GmbH