| 2 | DCI 700 User instructions............................Symbols used in the documentation....................... Warnings in the documentation........................Target group..............................Safety instructions............................Other applicable documents........................... Opening the DCI 700 Help Center...
Page 3
..........................Calibrating the rail sensor B80........................Troubleshooting............................After the DCI 700 is switched on the screeen remains dark and the operating display does not light up on monitor..............................Touchscreen not responding.........................
Electrotechnical knowledge for working on electrotechnical systems and equipment (see accident prevention regu‐ lation for electrical systems and equipment, e. g. DGUV V3 in Germany) All warranty claims (personal injury, faulty equipment) are rendered null and void if the DCI 700 is opened or modi‐ fied by unauthorized individuals.
DCI 700 | 5 | en • 1 689 979 860 – Important information and safety instructions for Bosch Diesel Test Equipment • Service information 200108_084 – Information regarding DGUV regulation 3 for electrical systems and equipment • DCI 700 Help Center...
| 6 | DCI 700 1.10 Disposal 1.10.1 Substances hazardous to water Substances hazardous to water must be disposed of in accordance with the applicable regulations. Oil, grease and refuse containing oil or grease (e.g. filters) are hazardous to water and the environment. Sub‐...
Page 7
DCI 700 | 7 | en 2: Rear view of DCI 700 (1) Cover for heat exchanger compartment and test oil area (2) Hydraulics compartment cover 3: Test area (1) Storage tray (2) Storage compartment with holders for the accessories...
Page 8
| 8 | DCI 700 4: Ports (1) Return test connection for injectors A and B (2) Injector A actuation port (3) Injector B actuation port (4) Injection test connection for injectors A, B, C and D (5) Return test connection for injectors C and D...
Page 9
DCI 700 | 9 | en 6: Test oil tank pulled out (1) Filling level indicator for minimum quantity (min.) (2) Filling level indicator for maximum quantity (max.) (3) Fastening screw for the test oil tank cap (4) Test oil tank cap...
Page 10
| 10 | DCI 700 7: Motor compartment and electronics compartment open (1) Front cover of electronic control (2) Drive motor (3) Counterweight (4) Electrical cabinet 1 689 975 289 | 2020-05-06 Robert Bosch GmbH...
DCI 700 | 11 | en 8: Back of DCI 700 (1) Rear cover of electronic control (2) Measurement block return channels C and D (3) Measurement block for injection (4) Measurement block return channels A and B (5) Heat exchanger...
| 12 | DCI 700 (4) Frequency converter A1 (5) Power supply unit G1 – 24 V voltage supply for circuit board A2 (6) Circuit breaker F1 – Main protection, 16 A (200 V version only) (7) Contactor Q2 – Main contactor (8) Contactor Q3 –...
Page 13
DCI 700 | 13 | en (2) Port X101 (RJ45) – Communication to frequency converter A1 (3) USB port X103 – Communication to processor unit 1 2 3 4 5 6 7 8 9 10111213141516 458929-13_Pal 12: LED overview (1) V49 –...
| 14 | DCI 700 3.1.3 Measurement block return A-B 14: Measurement block return channels A and B (1) Pressure control valve K14 (2) Temperature sensor B54 (3) Flow meter T24 for channel D (4) Flow meter T23 for channel C...
DCI 700 | 15 | en 3.1.4 Measurement block return C-D 15: Measurement block return channels C and D (1) Pressure control valve K12 (2) Temperature sensor B52 (3) Flow meter T22 for channel D (4) Flow meter T21 for channel C...
DCI 700 | 17 | en ATX12V1 Battery USB2_3 LVDS1 COM6 COM4 RJ-45 RJ-45 COM Port1 COM Port3 Mouse Line USB 2.0 USB 3.0 USB1 USB1 COM Port2 VGA1 USB0 USB0 Mic.In Keybo. 458929-17_Pal 18: Connections and jumper settings for motherboard A3...
Safety shutdown The safety shutdown protects the DCI 700 from overheating and is activated in the following situations: • Float switch B1 in the test oil tank has been actuated, e.g. in response to insufficient test oil in the test oil tank.
Removing the cover 5.1.3 Removing the protective doors Voraussetzungen: Before removing the protective door, disconnect the DCI 700 at the main switch and secure against reactiva‐ tion. 1. Open the protective door (3). The door contact for the safety switch must be located outside the switch box for door monitoring (1).
DCI 700 | 21 | en 27: Removing the protective door 3. Place the protective door on a clean and soft surface. 5.1.4 Removing the pump plate 1. Swivel the high-pressure rail to position "P". and 5). Always loosen pressure line fittings at the adapter nut.
Page 22
| 22 | DCI 700 28: Loosening the coupling 8. Remove 4 Torx screws (2) and spring washers. and 3) into the pump plate. 9. Screw 2 M5 screws and 3) alternately until the two spacer sleeves (4) can be re‐...
DCI 700 | 23 | en 5.1.5 Removing the high-pressure pump 30: Removing the pump plate 1. Remove hex nut (1) and lock washer (2). Insert a 10 mm round rod into the hole in the pump drive plate and hold the pump drive plate securely while loosening the hex.
| 24 | DCI 700 5.1.6 Assembling the high-pressure pump 32: Removing the pump plate 1. Remove the high-pressure pump from the packaging and place it aside. Do not remove the sealing plugs. 2. Place the pump plate (5) on the high-pressure pump (6).
DCI 700 | 25 | en 33: Attaching the pump drive plate 10. Remove all sealing plugs from the high-pressure pump. 5.1.7 Attaching the pump plate 1. Check whether the thrust rings (1) have been tightened on both pressure lines (left-hand thread). Remove the adapter nuts and turn the thrust rings counterclockwise as far as possible.
Page 26
| 26 | DCI 700 458929-38_Pal 35: Attaching the pump plate 4. Place the two spacer sleeves (2) between the pump drive plate (1) and coupling (3). If the spacers sleeves can‐ not be inserted because there is not enough space between the pump drive plate (1) and coupling (3), move the pump plate a bit farther away from the rotating frame.
2. Lift the protective door slightly and tilt forwards until the top guide roller can be set on the rail. 38: Installing the protective door 5.1.9 Leak tightness test Connecting and testing injectors (see DCI 700 Help Center). Robert Bosch GmbH 1 689 975 289 | 2020-05-06...
Preparation 1. Close all applications and shut down the operating system. 2. Disconnect the DCI 700 at the main switch and secure against reactivation. 3. Unplug the mains plug or disconnect from mains electricity. 1 689 975 289 | 2020-05-06...
DCI 700 | 29 | en 5.2.2 Removing the cover from the hydraulics compartment The cover is secured by means of a retaining device and cannot be tilted backwards. The cover must be removed by 2 people. and 3). The square box wrench is included in the 1.
| 30 | DCI 700 42: Removing the upper cover from the hydraulics compartment 5.2.4 Removing the flow meter Make sure that the surroundings and air are clean when replacing the flow meter. When performing repairs, make sure no other work is in progress which could emit particles into the air. If these requirements are not satisfied, then replace the flow meter at a clean workplace that has an extraction device.
Page 31
DCI 700 | 31 | en 43: Quantity measurement block with fan assembly 4. Remove the connection cable (2) from the flow meter (1). 44: Flow meter with connection cable 5. Remove both fastening screws. 6. Remove the flow meter (1) and both O-rings from the spacer plate (2).
| 32 | DCI 700 45: Replacing the flow meter 7. Do not leave the measurement block open for long without the flow meter installed. Install the new flow meter immediately. 5.2.5 Installing the flow meter The flow meter must be installed immediately after the blind plugs have been removed (risk of contamina‐...
Page 33
DCI 700 | 33 | en 47: Replacing the flow meter 7. Attach connection cable to the flow meter. 8. Using a wrench (1), loosen the hex nut on the plug. Do not remove the hex nut. 9. Turn and align the connection cable (2). The connection cable must point down.
12. Connect both connection cables from the fan assembly to connection cables M6 and M7. 5.2.6 Entering the calibration values 1. Switch on the DCI 700 at the main switch. 2. Start the DCI software. 3. If a mouse is not connected, connect a mouse to an unused USB port of the processor unit, 4.
Page 35
DCI 700 | 35 | en 51: Rear view of DCI 700 - Arrangement of the flow meters (1) Flow meter T22 for injector D return (2) Flow meter T21 for injector C return (3) Flow meter T14 for injector D quantity...
| 36 | DCI 700 5.2.7 Final steps Connecting and testing injectors (see DCI 700 Help Center). WARNING Risk of injury from spraying test oil! Wear safety goggles. WARNING Risk of trapping in rotating parts! Maintain a sufficient distance from rotating parts.
5.3.1 Preparation 1. Close all applications and shut down the operating system. 2. Disconnect the DCI 700 at the main switch and secure against reactivation. 3. Unplug the mains plug or disconnect from mains electricity. Robert Bosch GmbH 1 689 975 289 | 2020-05-06...
After switching off the unit, wait 5 minutes to allow the charged capacitors in the frequency converter to discharge. Before beginning work, make sure the DCI 700 and devices are not live. Removing the protective cover 1. Remove the Torx screws (1) and with washer.
Page 39
DCI 700 | 39 | en 57: Opening the electrical cabinet Removing the mounting panel and placing it aside 1. Slide 2 rectangular wooden strips measuring 59 x 59 350 mm (4) under the mounting panel (1) and rest them on the beams of the test bench frame.
| 40 | DCI 700 458929-43_Pal 59: Mounting panel resting on wooden strips 5.3.4 Removing frequency converter A1 1. Disconnect all connection cables from the frequency converter A1 (3). 2. Remove circuit board A6 (2). 3. Remove the 4 Torx screws (1).
Page 41
DCI 700 | 41 | en 61: Frequency converter A1 4. Set frequency converter A1 on the mounting panel. Make sure that no cables are pinched or damaged. 5. Fasten frequency converter A1 to the mounting panel with 4 Torx screws (1) and washers.
| 42 | DCI 700 63: Protective conductor connection on the frequency converter 10. Connect voltage supply to frequency converter A1 (refer to circuit diagram): — Connect wire from contactor Q2/2 (T1) to connection L1 of the frequency converter A1.
Page 43
DCI 700 | 43 | en 458929-49_Pal 65: Fastening the mounting panel 6. Use 2 Torx screws M6 x 16 mm and washers to secure cover (1) to the mounting panel. 458929-50_Pal 66: Fastening the cover 7. Use Torx screws M6 x 16 mm (3 and 5) and washers to secure protective cover (4). While attaching it, make sure the protective conductor is connected to the cover.
Preparation 1. Close all applications and shut down the operating system. 2. Disconnect the DCI 700 at the main switch and secure against reactivation. 3. Unplug the mains plug or disconnect from mains electricity. 1 689 975 289 | 2020-05-06...
DCI 700 | 45 | en 5.4.2 Removing the cover from the electronics compartment 1. Close the protective door. 2. Use a square box wrench to open the locking mechanisms (1). The square box wrench is included in the scope of delivery of DCI 700.
| 46 | DCI 700 70: Opening the cover 2. With the aid of a second person, raise the cover, detach it, and remove it by lifting it. 71: Removing the cover 5.4.4 Removing the upper cover from the hydraulics compartment 1.
DCI 700 | 47 | en 72: Removing the upper cover from the hydraulics compartment 5.4.5 Removing circuit board A3 Take note of the ESD handling instructions in EDIS, and remove components with care. Extreme bending may damage the circuit board.
Page 48
| 48 | DCI 700 73: Removing the circuit board cover 4. Remove the protective conductor on the front circuit board cover (2). 5. Remove the 2 cylinder head screws (1) and washers. 6. Lift the front circuit board cover (2), and carefully pull it up and out.
DCI 700 | 49 | en 75: Removing circuit board A3 5.4.6 Installing circuit board A3 Take note of the ESD handling instructions in EDIS, and remove components with care. Extreme bending may damage the circuit board. When installing the circuit board, take care not to slide it across a sheet metal edge of the test bench. This may cause components on the circuit board to get detached or damaged.
Page 50
| 50 | DCI 700 77: Installing circuit board A3 5. Connect all connection cables to circuit board A3 (see circuit diagram). 6. Carefully, insert the front circuit board cover (2) below the guide at an angle and set it down. Make sure not to detach or pinch any cables.
DCI 700 | 51 | en 79: Installing the circuit board cover 12. Attach the protective conductor to the rear circuit board cover (2). 13. Check the protective conductor in accordance with DGUV A3. 5.4.7 Installing the cover on the hydraulics compartment 1.
2. Press cover against the test bench frame. and 3). The square box wrench is included 3. Using a square box wrench, close the two electrical cabinet locks in the scope of delivery of the DCI 700. 82: Opening the cover 5.4.9...
Installing the cover on the electronics compartment 5.4.10 Final steps 1. Connect the power supply cable to the mains voltage system. 2. Switch on DCI 700 at the main switch. 3. Start the "DCI" software. 57 "Updating the firmware").
Page 54
7. Seal high-pressure connections A to C with threaded plugs. Tightening torque: 25 Nm – 30 Nm. 8. Select <Start>. The DCI 700 starts and the first pressure point is approached. 9. Once the measured value in the Reference [MPa] field is stable and <Next> is active, save the measured value and approach the next pressure point by pressing <Next>.
After the DCI 700 is switched on the screeen remains dark and the operating display does not light up on the monitor After the DCI 700 is switched on, the screen remains dark and the operating display does not light up on the monitor.
---Separator--- System recovery If the current software version causes problems or if the DCI 700 is to be sold, reset the DCI 700 to factory set‐ tings. System recovery will delete all data and settings from the DCI 700, e.g. licensing information, log files, user settings, protocols, images.
2. Use <Close> to ignore the message. 3. Load the backed-up data and settings again (see DCI 700 Help Center). If a data backup is not available, all settings must be made again (see DCI 700 installation instructions). 4. Select the "Subscription" (Licensing) tab.
Page 58
| 58 | DCI 700 3. Select Status from the header. 4. In the line "Firmware version," check the status. If there is a green checkmark, the firmware version is up to date. No further steps are required. If there is an orange exclamation point, a new firmware version is available for installation.