5.2.2

Removing the cover from the hydraulics compartment

(2)
The cover
is secured by means of a retaining device and cannot be tilted backwards. The cover must be
removed by 2 people.
1. Use a square box wrench to open both locking mechanisms
scope of delivery of DCI 700.
1
2
 40:
Opening the cover
2. With the aid of a second person, raise the cover, detach it, and remove it by lifting it.
 41:
Removing the cover
---
5.2.3

Removing the upper cover from the hydraulics compartment

1. Remove the 3 Torx cylinder head screws (1).
2. Remove the cover from the hydraulics compartment (2).
Robert Bosch GmbH
(1
3
and 3). The square box wrench is included in the
1 689 975 289 | 2020-05-06