Power on and power off problems

Use this information to resolve issues when powering on or powering off the server.
• "Embedded hypervisor is not in the boot list" on page 406
• "The power button does not work (server does not start)" on page 407
• "Server does not power on" on page 408
Embedded hypervisor is not in the boot list
Complete the following steps until the problem is solved.
1. If the server has been installed, moved, or serviced recently, or if this is the first time the embedded
hypervisor is being used, make sure that the device is connected properly and that there is no physical
damage to the connectors.
2. See the documentation that comes with the optional embedded hypervisor flash device for setup and
configuration information.
3. Check
https://static.lenovo.com/us/en/serverproven/index.shtml
device is supported for the server.
4. Make sure that the embedded hypervisor device is listed in the list of available boot options. From the
management controller user interface, click Server Configuration ➙ Boot Options.
For information about accessing the management controller user interface, see the XClarity Controller
product documentation:
http://sysmgt.lenovofiles.com/help/topic/com.lenovo.systems.management.xcc.doc/dw1lm_c_chapter2_
openingandusing.html
5. Check
http://datacentersupport.lenovo.com
hypervisor and the server.
6. Make sure that other software works on the server to ensure that it is working properly.
ThinkSystem SR665 Maintenance Manual
406
to validate that the embedded hypervisor
for any tech tips (service bulletins) related to the embedded