Lenovo ThinkSystem SR665 Maintenance Manual page 370

Hide thumbs Also See for ThinkSystem SR665:
Table of Contents

Advertisement

Procedure
Step 1.
Touch the static-protective package that contains the new riser card to any unpainted surface on
the outside of the server. Then, take the new riser card out of the package and place it on a static-
protective surface.
Step 2.
Install the riser card to the riser bracket. See Step 2 Install a riser card on page 351.
Step 3.
Install PCIe adapters. See Step 3 Install a PCIe adapter on page 352.
Step 4.
Check the rearwall matrix and decide which rearwall brackets need to be installed or removed for
installing your riser assemblies. See "Rearwall bracket replacement" on page 306
Step 5.
Install a riser 3 assembly. Align the securing clip at the end of the riser cage with the pin on the rear
chassis, the pin on the right side of the riser cage with the pin slot on the C1 rearwall bracket.
Carefully put down the riser 3 assembly until it is securely seated.
Figure 174. Riser 3 assembly installation
After you finish
1. Refer to Chapter 3 "Internal cable routing" on page 57 to connect any cables to the PCIe adapters.
2. Complete the parts replacement. See "Complete the parts replacement" on page 397.
ThinkSystem SR665 Maintenance Manual
360