3.0 Setup
Bottom line shows
current "saved" setting
MENU
POWER ON
Norm
HOME
If this setting is correct,
press MENU button to
access different menu items
press
Figu r e 3 - 1 2 , Pow e r On Se le ct ion s

3.3.12 TECH Menu

TECH – This menu provides access to read only system information that
can assist service technicians in troubleshooting. It also offers a selection
that enables you to return all system settings to the original factory default
values, and another that locks some setup menus.
Scroll to the end of the remote's menus until "TECH, Press ON" appears.
Press the ON/OFF CHANGE button to access these selections. Continue to
press the ON/OFF CHANGE button to view each TECH menu item.
 Bat Temp: Displays the temperature of the battery temperature sensor
(BTS)—if connected.
 Xfm Temp: Displays the temperature of the inverter's transformer.
 FET Temp: Displays the temperature of the FETs (Field Effect Transistors).
 Inverter Rev: Displays the fi rmware revision level of the inverter.
 Remote Rev: Displays the fi rmware revision level of the remote.
 Model: Displays the model number of the connected inverter.
Info: If "Model Unknown" displays, the remote is unable to
determine the inverter model. This may be due to an inverter
revision newer than the remote. All remote menu selections/
features that are available in the inverter will function normally.
 Ext Ctrl: Magnum has an open protocol policy that allows certain
functions (AC I n, Charge Rat e, & VAC Dropout settings) of the
inverter/charger to be controlled externally—such as with a third party
communications device.
N o – there is no external device controlling any of the inverter's settings.
I N T – an external device is controlling the setting—however, the
external device has not changed the setting at this time.
EXT – an external device is controlling the setting—and, the external
device has changed the setting.
When an external device is connected, the above menus scroll across the
bottom line of the display. The I NT or EXT display denotes whether the
setting has been changed. Example: AC I N I NT...CHR% I NT...VAC EXT.
An external device is connected, the AC I N and Charge Rat e settings
have not been changed, but the VAC Dropout setting has been changed.
 SETUP: Allows you to Lock or Unlock the setup menus on your remote.
Press the SAVE/HOLD button to lock the setup menus (Lock) or to unlock
(Unlock) the setup menus.
N ot e : Except ion – AC I n m enu does not lock.