Tech Menu; Figure 3-14 Thru 3-18, Tech Menu Displays/Selection - Magnum Energy ME-RC Owner's Manual

Hide thumbs Also See for ME-RC:
Table of Contents

Advertisement

3.0 Setup

3.2.5 TECH Menu

The TECH menu pushbutton provides access to selections that are used to
assist service technicians in troubleshooting. It provides access to system in-
formation along with a selection that allows all system settings to be returned
to the original factory default values.
TECH: 0 Temperatures – This "read only" menu displays temperature read-
ings of the battery temperature sensor (if connected), the transformer, the FET's
(Field Effect Transistors) and a networked AGS (if installed).
TEC H
press
Status ...
BTS: **C/**F
Figure 3-14, TECH: 01 Temperatures Display
TECH: 02 Revisions – This "read only" menu displays the firmware revision
level of the inverter, remote and any optional accessory (i.e. AGS) that is
installed and networked.
TEC H
press
Status ...
Inverter: **
Figure 3-15, TECH: 02 Revisions Display
TECH: 03 Inv Model – This "read only" menu displays the model number of
the connected inverter.
TEC H
press
Status...
03 Inv Model
Figure 3-16, TECH: 03 Inv Model Display
Info: When "Model: UNKNOWN" is displayed, the remote is not able to
determine the inverter model, this is due to an older inverter model or
an inverter revision newer than the remote; all remote menu selections
and features that are available in the inverter will function normally.

rotate to
Status...
01 Temperatures
Status...
Tfmer: **C/**F
rotate to
Status...
02 Revisions
Status...
Remote: **
rotate to
press to select
Status ...
Status ...
FETs: **C/**F
AGS: **C/**F
press to select
Status ...
Status...
AGS: **
BMK: **
display show s
Status...
press
Model: ****
©2009 Magnum Energy Inc.
rotate to
desired
display :
rotate to
desired
display :
connected
inverter:

Hide quick links: