Flush Mount Installation Procedure; Figure 2-4, Flush Mounting The Me-Rc - Magnum Energy ME-RC Owner's Manual

Standard remote control
Hide thumbs Also See for ME-RC:
Table of Contents

Advertisement

2.0 Installation
2.4.1

Flush Mount Installation Procedure

To fl ush mount, the wall opening must have at least a 2" (5 cm) depth to
allow room for the remote and the cable.
1.
Cut an opening in the wall (Figure 2-4). Ensure there are no openings
around the display and enough material for the screws to secure the unit.
2.
Drill four pilot holes for the #8 x 3/4 screws that will attach the remote to
the wall (refer to Figure 2-3 for remote hole locations and dimensions).
3.
Route one end of the cable through the wall opening to the inverter/
charger, and then plug it into the RJ11 REMOTE port (blue label) on the
inverter/charger—inverter has DC power, but is OFF. See Figure 2-2.
4.
Take the other end of the remote cable and while plugging it into the
back of the ME-RC, view the remote's display to ensure the Power-up
Self Test initiates (see Section 2.5).
5.
If the self test is successful, secure the ME-RC to the wall using the
four supplied Phillips screws. If the self test is unsuccessful, refer to the
Troubleshooting section.

Figure 2-4, Flush Mounting the ME-RC

5
5.0"
(12.7 cm)
3.0"
(7.6 cm)
©2013 Magnum Energy, Inc.