CHAPTER
4
INSTALL THE SMARTRAX NODE
MOUNT THE SMARTRAX NODE
FIGURE 1. Node Mounting Location
1. Remove the plastic molding behind the seat by removing the nuts and bolts used to secure it.
2. Install the node mounting bracket (P/N 107-0172-084) in the tapped holes on the back wall of the cab using
four M6 hex bolts (P/N 311-0070-010), four washers (P/N 313-2300-009), and four 5/16" lock washers.
IMPORTANT:
Install the washers on the bottom bolts between the wall and the mounting plate to level the node. The
mounting plate must be within +/- 2° of level to the wall for the SmarTrax system to operate properly.
NOTE:
Install the node mounting bracket so that the cable connectors of the node (P/N 063-0173-228) face
the operators seat when installed.
Manual No. 016-5032-037 Rev. A
C AB COMPONENT
C H A P T E R 4
INSTALLATION
23