User Guide | Controller for appliance control, AK-CC55
Compact - continued
Alarms
Delay for temperature alarm
Delay for door alarm
Delay for temperature alarm after defrost
High alarm limit for thermostat 1
Low alarm limit for thermostat 1
High alarm limit for thermostat 2
Low alarm limit for thermostat 2
Alarm time delay or signal on the DI1 input
Alarm time delay or signal on the DI2 input
Signal for alarm thermostat. S4% (100%=S4, 0%=S3)
Compressor
Min. ON-time
Min. OFF-time
Time delay for cut-in of comp. 2
Switch mode for 2 compressor operation.
= 1 sequentially. = Cyclic 2
Defrost
Defrost method: 0=No, 1= EL, 2= gAs. 3=brine, 4=air
Defrost stop temperature
Interval between defrost starts
Max. defrost duration
Displacement of time on cut-in of defrost at start-up
Drip off time
Delay for fan start after defrost
Fan start temperature
Fan cut-in during defrost
0: Stopped
1: Running
2: Running during pump down and defrost
3: Running but stops at the temperature set in d41
Defrost sensor: 0 =Stop on time, 1=S5, 2=S4
Pump down delay
Max. aggregate refrigeration time between two
defrosts
Rail heat during defrost
0=off. 1=on. 2=Pulsating
Max. duration of -d- in display
Temperature limit for fan stop during defrost when
d09 is set to 3
Injection control function
Max. value of superheat reference
Min. value of superheat reference
MOP temperature. Off if MOP temp. = 15.0 °C
Cycle time of AKV pulsation
Only for trained personnel
Cycle time at PWM pulse width modulating
Max. opening degree at PWM
Min. opening degree at PWM
Expert setting. Wind up at PWM
Expert setting. Kp at PWM
Expert setting. Tn at PWM
© Danfoss | DCS (vt) | 2019.09
R-W
Code
1
2 3
4
1-2
A03
1
1
1
1
1-2
A04
1
1
1
1
1-2
A12
1
1
1
1
1-2
A13
1
1
1
1
1-2
A14
1
1
1
1
1-2
A20
1
1
1
1
1-2
A21
1
1
1
1
1-2
A27
1
1
1
1
1-2
A28
1
1
1
1
1-2
A36
1
1
1
1
1-2
c01
1
1
1
1
1-2
c02
1
1
1
1
1-2
c05
1
1-2
c08
1
1-3
d01
1
1
1
1
1-2
d02
1
1
1
1
1-2
d03
1
1
1
1
1-2
d04
1
1
1
1
1-2
d05
1
1
1
1
1-2
d06
1
1
1
1
1-2
d07
1
1
1
1
1-2
d08
1
1
1
1
1-2
d09
1
1
1
1
1-2
d10
1
1
1
1
1-2
d16
1
1
1
1
1-2
d18
1
1
1
1
1-2
d27
1
1
1
1
1-2
d40
1
1
1
1
1-2
d41
1
1
1
1
1-2
n09
1-2
n10
1-2
n11
1-2*
n13
1-2
n63
1
1
1
1
1-2
n64
1
1
1
1
1-2
n65
1
1
1
1
1-2
n66
1
1
1
1
1-2
n67
1
1
1
1
1-2
n68
1
1
1
1
5
6 7
8
9
Min.
1
1
1
1
1 0 min.
1
1
1
1
1 0 min.
1
1
1
1
1 0 min.
1
1
1
1
1 -50 °C
1
1
1
1
1 -50 °C
1
1
1
1
1 -50 °C
1
1
1
1
1 -50 °C
0 min.
1
1
1
1
1 0 min.
1
1
1
1
1 0 %
1
1 0 min.
1
1 0 min.
1 0 sec
1 1
1
1
1
1
1 0/No
1
1
1
1
1 0 °C
1
1
1
1
1 0 hrs/Off 240 hrs
1
1
1
1
1 0 min.
1
1
1
1
1 0 min.
1
1
1
1
1 0 min.
1
1
1
1
1 0 min.
1
1
1
1
1 -50 °C
1
1
1
1
1 0
1
1
1
1
1 0
1
1
1
1
1 0 min.
1
1
1
1
1 0 hrs
1
1
1
1
1 0
1
1
1
1
1 5 min.
1
1
1
1
1 -20 °C
1
1
1
1
1 "n10"
1
1
1
1
1 2 °C
1
1
1
1
1 -50 °C
1
1
1
1
1 3 sec
30 sec
"n65"
0 %
0.2
0.5
60 sec
BC308437742037en-000101 | 21
Max.
Fac.
Actual
240 min.
30
240 min.
60
240 min.
90
50 °C
8
50 °C
-30
50 °C
8
50 °C
-30
240 min.
30
240 min.
30
100 %
100
30 min.
0
30 min.
0
999 sec
5
2
2
4/Air
1/EL
50 °C
6
8
360 min.
45
240 min.
0
60 min.
0
60 min.
0
10 °C
-5
3
1
2
0
60 min.
0
240 hrs
0/OFF
2
1
240 min.
30 min.
20 °C
0
20 °C
12
"n09"
3
15 °C
15
6 sec
6
900 sec
300
100 %
100
"n64"
0
1.0
1.0
10.0
4.0
1800 sec
300