Danfoss AK-CC55 User Manual page 31

Controller for appliance control
Hide thumbs Also See for AK-CC55:
Table of Contents

Advertisement

User Guide | Controller for appliance control, AK-CC55
Single Coil - continued
Configuration of relay output DO3: 0=not used, 1=fan,
2=fan Eco, 3=defrost, 4=rail heat, 5=alarm, 6=light,
7=night blinds, 8=compressor, 9=compressor 2,
10=heating element
Configuration of relay output DO4: 0=not used, 1=fan,
2=fan Eco, 3=defrost, 4=rail heat, 5=alarm, 6=light,
7=night blinds, 8=compressor, 9=compressor 2,
10=heating element
Configuration of relay output DO5: 0=not used, 1=fan,
2=fan Eco, 3=defrost, 4=rail heat, 5=alarm, 6=light,
7=night blinds, 8=compressor, 9=compressor 2,
10=heating element
Configuration of relay output DO6: 0=not used, 1=fan,
2=fan Eco, 3=defrost, 4=rail heat, 5=alarm, 6=light,
7=night blinds, 8=compressor, 9=compressor 2,
10=heating element
Configuration of analogue output AO1: 0=not used.
1=rail heat PWM
Manual control of output: AKV valve 0-100%
Manual control of output: Compressor1/LLSV
Manual control of output: Fan
Manual control of output: Defrost
Manual control of output: Rail heat
Manual control of output: Alarm
Manual control of output: Light
Manual control of output: Valve in suction line
Manual control of output: Compressor 2
Manual control of output: Hot gas valve
Manual control of output: Night blinds
Manual control of output: Defrost 2
Manual control of output: Heating element
Manual control of output: Fan Eco
Manual control of output: Drain
Manual control of output: Humidity
Manual control of output: Rail heat PWM
Define which food temperature measurement to
display in U72: 1=thermostat temperature, 2=alarm
temperature, 3=S3, 4=S6
Service
Control mode
Temperature measured with S5 sensor
Status on DI1 input. on/1=closed
Actual defrost time (minutes)
Temperature measured with S3 sensor
Status on night operation (on or off ) 1=on
Temperature measured with S4 sensor
Thermostat temperature
Runtime of thermostat (cooling time) in minutes
Temperature of S2 evaporator outlet temp.
Superheat across evaporator
Reference of superheat control
Opening degree of AKV valve
Evaporating pressure Po (relative)
Evaporator temperature To (Calculated)
Temperature measured with S6 sensor
(product temperature)
Status on DI2 input. on/1=closed
Air temperature . Weighted S3 and S4
Measured temperature for alarm thermostat
© Danfoss | DCS (vt) | 2019.09
R-W Code
1
2 3
4
1-3* q03
1-3* q04
1-3* q05
1-3* q06
1-3* q09
1
1
1
1
1-2** q11
1
1
1
1
1-2** q12
1
1
1
1-2** q13
1
1
1
1
1-2** q14
1
1
1
1
1-2** q15
1
1
1
1-2** q16
1
1
1
1-2** q17
1
1
1
1-2** q18
1-2** q19
1-2** q20
1-2** q21
1-2** q22
1-2** q23
1-2** q24
1-2** q25
1-2** q26
1-2** q27
1
1
1
1
1-2* q39
1
1
1
1
0-0
u00
1
1
1
1
0-0
u09
1
1
1
1
0-0
u10
1
1
1
1
0-0
u11
1
1
1
1
0-0
u12
1
1
1
1
0-0
u13
1
1
1
1
0-0
u16
1
1
1
1
0-0
u17
1
1
1
1
0-0
u18
1
1
1
1
0-0
u20
1
1
1
1
0-0
u21
1
1
1
1
0-0
u22
1
1
1
1
0-0
u23
1
1
1
1
0-0
u25
1
1
1
1
0-0
u26
1
1
1
1
0-0
u36
1
1
1
1
0-0
u37
1
1
1
1
0-0
u56
1
1
1
1
0-0
u57
1
1
1
1
5
6 7
8
9
Min.
1 0
1 0
1 0
1 0
1
1
1
1
1 0
1
1
1
1
1 0 %
1 0/Off
1
1
1
1
1 0/Off
1
1
1
1 0/Off
1
1 0/Off
1
1
1
1 0/Off
1
1
1
1
1 0/Off
1
0/Off
1 0/Off
1
0/Off
1 0/Off
1
0/Off
1 0/Off
1 0/Off
1
0/Off
1
0/Off
1
1
1
1
1 0 %
1
1
1
1
1 1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
BC308437742037en-000101 | 31
Max.
Fac.
Actual
10
8
10
9
10
3
10
1
1
0
100 %
0
1/On
0/Off
1/On
0/Off
1/On
0/Off
1/On
0/Off
1/On
0/Off
1/On
0/Off
1/On
0/Off
1/On
0/Off
1/On
0/Off
1/On
0/Off
1/On
0/Off
1/On
0/Off
1/On
0/Off
1/On
0/Off
1/On
0/Off
100 %
0
4
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents