Fan; Real Time Clock; Miscellaneous - Danfoss AK-CC55 User Manual

Controller for appliance control
Hide thumbs Also See for AK-CC55:
Table of Contents

Advertisement

User Guide | Controller for appliance control, AK-CC55
Compact - continued

Fan

Fan stop temperature (S5)
Pulse operation on fans: 0=No pulse operation, 1=At
thermostat cut-outs only, 2= Only at thermostat
cut-outs during night operation
Cycle time for fan pulsation (on-time + off-time)
On-time in % of cycle time

Real time clock

Defrost start via defrost schedule: 0/off=no.
1/on=yes
Six start times for defrost.
Setting of hours.
0=OFF
Six start times for defrost.
Setting of minutes.
0=OFF
Clock - Setting of hours
Clock - Setting of minutes
Clock - Setting of date
Clock - Setting of month
Clock - Setting of year
Defrost schedule for Mondays is active at On/1
Defrost schedule for Tuesdays is active at On/1
Defrost schedule for Wednesdays is active at On/1
Defrost schedule for Thursdays is active at On/1
Defrost schedule for Fridays is active at On/1
Defrost schedule for Saturdays is active at On/1
Defrost schedule for Sundays is active at On/1

Miscellaneous

Delay of output signals after power failure
Input signal on DI1. Function:
0=not used. 1=status on DI1. 2=door function
with alarm when open. 3=door alarm when open.
4=defrost start (pulse-signal). 5=ext.main switch.
6=night operation. 7=thermostat band changeover
(activate r21). 8=alarm function when closed.
9=alarm function when open. 10=Appliance cleaning
(pulse signal). 11=forced cooling at hot gas defrost.
12=Open night cover. 14=Refrigeration stopped
(forced closing). 15=case shutdown. 16=light.
20=Refrigerant alarm. 21= adaptive liquid control
when short-circuited.
Network address
Access code 3 (all settings)
Used sensor type: 0=Pt1000, 1=PTC1000, 2=Ntc5K,
3=Ntc10K. (S2 and S6 are not affected. They are
always Pt1000 ohms)
Max. hold time after coordinated defrost
Select signal for display view. S4%
(100%=S4, 0%=S3)
Pressure transmitter working range – min. value
Pressure transmitter working range – max. value
22 | BC308437742037en-000101
R-W
Code
1
2 3
4
1-2
F04
1
1
1
1
1-2
F05
1
1
1
1
1-2
F06
1
1
1
1
1-2
F07
1
1
1
1
1-2
t00
1
1
1
1
1-2
t01 -
1
1
1
1
t06
1-2
t11 -
1
1
1
1
t16
0-1
t07
1
1
1
1
0-1
t08
1
1
1
1
0-1
t45
1
1
1
1
0-1
t46
1
1
1
1
0-1
t47
1
1
1
1
1-2
t51
1
1
1
1
1-2
t52
1
1
1
1
1-2
t53
1
1
1
1
1-2
t54
1
1
1
1
1-2
t55
1
1
1
1
1-2
t56
1
1
1
1
1-2
t57
1
1
1
1
1-2
o01
1
1
1
1
1-2*
o02
1
1
1
1
1-3*
o03
1
1
1
1
3-3
o05
1
1
1
1
1-3*
o06
1
1
1
1
1-2
o16
1
1
1
1
1-2
o17
1
1
1
1
1-3*
o20
1-3*
o21
5
6 7
8
9
Min.
1
1
1
1
1 -50 °C
1
1
1
1
1 0
1
1
1
1
1 1 min.
1
1
1
1
1 0 %
1
1
1
1
1 0/off
1
1
1
1
1 0 hrs
1
1
1
1
1 0 min.
1
1
1
1
1 0 hr
1
1
1
1
1 0 min.
1
1
1
1
1 1 day
1
1
1
1
1 1 mon.
1
1
1
1
1 0 years
1
1
1
1
1 0/Off
1
1
1
1
1 0/Off
1
1
1
1
1 0/Off
1
1
1
1
1 0/Off
1
1
1
1
1 0/Off
1
1
1
1
1 0/Off
1
1
1
1
1 0/Off
1
1
1
1
1 0 sec
0
1
1
1
1
1 0
1
1
1
1
1 0
1
1
1
1
1 0/Pt
1
1
1
1
1 0 min.
1
1
1
1
1 0 %
1
1
1
1
1 -1 bar
1
1
1
1
1 6 bar
Max.
Fac.
Actual
50 °C
50
2
0
30 min.
5
100 %
100
1/on
0/off
23 hrs
0
59 min.
0
23 hrs
0
59 min.
0
31 days
1
12 mon.
1
99 years
0
1/On
1/On
1/On
1/On
1/On
1/On
1/On
1/On
1/On
1/On
1/On
1/On
1/On
1/On
600 sec
5
20
0
240
0
999
0
3/N10
0/Pt
360 min.
20
100 %
100
5 bar
-1
200 bar
12