Danfoss AK-CC55 User Manual page 34

Controller for appliance control
Hide thumbs Also See for AK-CC55:
Table of Contents

Advertisement

User Guide | Controller for appliance control, AK-CC55
Multi Coil - continued
Low alarm limit for thermostat 2
Alarm time delay or signal on the DI1 input
Alarm time delay or signal on the DI2 input
Defrost
Defrost method: 0=No, 1= EL, 4=air
Defrost stop temperature
Interval between defrost starts
Max. defrost duration
Displacement of time on cut-in of defrost at start-up
Drip off time
Delay for fan start after defrost
Fan start temperature
Fan cut-in during defrost
0: Stopped
1: Running
2: Running during pump down and defrost
3: Running but stops at the temperature set in d41
Defrost sensor: 0 =Stop on time, 1=S5, 2=S4
Pump down delay
Max. aggregate refrigeration time between two defrosts
Rail heat during defrost
0=off. 1=on. 2=Pulsating
Max. duration of -d- in display
Temperature limit for fan stop during defrost when d09 is set to 3
Injection control function
Max. value of superheat reference
Min. value of superheat reference
MOP temperature. Off if MOP temp. = 15.0 °C
Cycle time of AKV pulsation
Only for trained personnel
Fan
Fan stop temperature (S5)
Pulse operation on fans: 0=No pulse operation, 1=At thermostat
cut-outs only, 2= Only at thermostat cut-outs during night operation
Cycle time for fan pulsation (on-time + off-time)
On-time in % of cycle time
Real time clock
Defrost start via defrost schedule: 0/off=no.
1/on=yes
Six start times for defrost.
Setting of hours.
0=OFF
Six start times for defrost.
Setting of minutes.
0=OFF
Clock - Setting of hours
Clock - Setting of minutes
Clock - Setting of date
Clock - Setting of month
Clock - Setting of year
Defrost schedule for Mondays is active at On/1
Defrost schedule for Tuesdays is active at On/1
Defrost schedule for Wednesdays is active at On/1
Defrost schedule for Thursdays is active at On/1
Defrost schedule for Fridays is active at On/1
Defrost schedule for Saturdays is active at On/1
Defrost schedule for Sundays is active at On/1
34 | BC308437742037en-000101
R-W
Code
1
2 3
4
1-2
A21
1
1
1
1
1-2
A27
1
1
1-2
A28
1
1
1
1
1-3
d01
1
1
1
1
1-2
d02
1
1
1
1
1-2
d03
1
1
1
1
1-2
d04
1
1
1
1
1-2
d05
1
1
1
1
1-2
d06
1
1
1
1
1-2
d07
1
1
1
1
1-2
d08
1
1
1
1
1-2
d09
1
1
1
1
1-2
d10
1
1
1
1
1-2
d16
1
1
1
1
1-2
d18
1
1
1
1
1-2
d27
1
1
1
1
1-2
d40
1
1
1
1
1-2
d41
1
1
1
1
1-2
n09
1
1
1
1
1-2
n10
1
1
1
1
1-2
n11
1
1
1
1
1-2*
n13
1
1
1
1
1-2
F04
1
1
1
1
1-2
F05
1
1
1
1
1-2
F06
1
1
1
1
1-2
F07
1
1
1
1
1-2
t00
1
1
1
1
1-2
t01 -
1
1
1
1
t06
1-2
t11 -
1
1
1
1
t16
0-1
t07
1
1
1
1
0-1
t08
1
1
1
1
0-1
t45
1
1
1
1
0-1
t46
1
1
1
1
0-1
t47
1
1
1
1
1-2
t51
1
1
1
1
1-2
t52
1
1
1
1
1-2
t53
1
1
1
1
1-2
t54
1
1
1
1
1-2
t55
1
1
1
1
1-2
t56
1
1
1
1
1-2
t57
1
1
1
1
5
Min.
Max.
Fac.
1 -50 °C
50 °C
-30
0 min.
240 min.
30
1 0 min.
240 min.
30
1 0/No
4/Air
1/EL
1 0°C
50°C
6
1 0 hrs/Off 240 hrs
8
1 0 min.
360 min.
45
1 0 min.
240 min.
0
1 0 min.
60 min.
0
1 0 min.
60 min.
0
1 -50 °C
10 °C
-5
1 0
3
1
1 0
2
0
1 0 min.
60 min.
0
1 0 hrs
240 hrs
0/OFF
1 0
2
1
1 5 min.
240 min.
30 min.
1 -20 °C
20 °C
0
1 "n10"
20 °C
12
1 2 °C
"n09"
3
1 -50 °C
15 °C
15
1 3 sec
6 sec
6
1 -50 °C
50 °C
50
1 0
2
0
1 1 min.
30 min.
5
1 0 %
100 %
100
1 0/off
1/on
0/off
1 0 hrs
23 hrs
0
1 0 min.
59 min.
0
1 0 hr
23 hrs
0
1 0 min.
59 min.
0
1 1 day
31 days
1
1 1 mon.
12 mon.
1
1 0 years
99 years
0
1 0/Off
1/On
1/On
1 0/Off
1/On
1/On
1 0/Off
1/On
1/On
1 0/Off
1/On
1/On
1 0/Off
1/On
1/On
1 0/Off
1/On
1/On
1 0/Off
1/On
1/On