Danfoss AK-CC55 User Manual page 32

Controller for appliance control
Hide thumbs Also See for AK-CC55:
Table of Contents

Advertisement

User Guide | Controller for appliance control, AK-CC55
Single Coil - continued
Status on relay for compressor/solenoid valve
Status on relay for fan
Status on relay for defrost
Status on relay for rail heat
Status on relay for alarm
Status on relay for light
Status on relay for valve in suction line
Status on relay for compressor 2
Temperature measured with S5B sensor
Temperature measured with S3B sensor
Status on relay for hot gas / drain valve
Status on relay for night blinds
Status on relay for defrost B
Status on relay for heat function
Readout of the actual rail heat effect via relay
1: Thermostat 1 operating, 2: Thermostat 2 operating
Status on high voltage input DI3
Readout of thermostat band in use
Readout of thermostat's actual cut-out value
Readout of status on the adaptive defrost
0: Off. Function is not activated and are zero-set
1: Sensor error or S3/S4 are reversed
2: Tuning is in progress
3: Normal
4: Light build-up of ice
5: Medium build-up of ice
6: Heavy build-up of ice
Number of defrosts carried out since the initial power
up or since the resetting of the function
Number of defrosts skipped since the initial power up
or since the resetting of the function
Readout of alarm air temp. Section B
Readout of display 2 value
Status of relay for ECO fan
Readout of signal quality for MODBUS communication 0-0
Status of relay to drain valve
Readout of measured humidity in %
Status of relay for humidity
Readout of rail heat effect via AO1 i %
Readout of measured food temperature
(defined in q39)
Readout of measured defrost stop temperature
(defined in d10)
Factory setting
If you need to return to the factory-set values, it can be done in this way:
- Cut off the supply voltage to the controller.
- Keep up
and down
arrow buttons depressed at the same time as you reconnect the supply voltage.
"
"
"
"
- When FAc is shown in the display, select "yes".
32 | BC308437742037en-000101
R-W Code
1
2 3
4
0-0
u58
1
1
1
0-0
u59
1
1
1
1
0-0
u60
1
1
1
1
0-0
u61
1
1
1
0-0
u62
1
1
1
0-0
u63
1
1
1
0-0
u64
0-0
u67
0-0
u75
0-0
u76
0-0
u80
0-0
u82
0-0
u83
0-0
u84
0-0
u85
1
1
1
1
0-0
u86
1
1
1
1
0-0
u87
1
1
1
1
0-0
u90
1
1
1
1
0-0
u91
1
1
1
1
0-0
U01
1
1
1
1
0-0
U10
1
1
1
1
0-0
U11
1
1
1
1
0-0
U34
0-0
U35
0-0
U37
U45
1
1
1
1
0-0
U55
0-0
U57
0-0
U58
0-0
U59
1
1
1
1
0-0
U72
1
1
1
1
0-0
U73
1
1
1
1
5
6 7
8
9
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
© Danfoss | DCS (vt) | 2019.09