User Guide | Controller for appliance control, AK-CC55
Menu survey — Single Coil version
Overview of outputs and applications
Application
1
2
3
4
5
6
7
8
9
See also wiring diagrams earlier in the User Guide.
•
= Optional
•
1) Custom set-up of relays
Menu set via display
Parameter
Function
Normal operation
Temperature (setpoint)
Thermostat
Differential
Max. limitation of setpoint setting
Min. limitation of setpoint setting
Temperature unit (°C/°F)
Correction of the signal from S4
Correction of the signal from S3
Manual service, stop regulation, start regulation (-1,
0, 1)
Displacement of reference during night operation
Define thermostat function
1=ON/OFF, 2=Modulating
Definition and weighting, if applicable, of thermostat
sensors - S4% (100%=S4, 0%=S3)
Time between melt periods
Duration of melt periods
Temperature setting for thermostat band 2 . As dif-
ferential use r01
Correction of the signal from S3B
Correction of the signal from S6
Definition and weighting, if applicable, of thermostat
sensors when night cover is on. (100%=S4, 0%=S3)
Heat function
Neutral zone between refrigeration and heat function
Time delay at switch between refrigeration and heat
function
Food type: use settings listed in table.
Min. limit for S4 temperature
R-W
If the operation is limited by a setting of one or more passwords, reading and setting the
parameter will be limited to:
R: This setting can be seen with password no. _ or higher.
W: This setting can be performed with password no. _ or higher (3 is the highest level).
*) Always required that the regulating is stopped, r12=0)
**) Always required that the regulating is stopped and set to manual service, r12= -1)
26 | BC308437742037en-000101
DO1
DO2
DO3
DO4
DO5
suction
drain
hotgas
B
A
humidity
•
•
•
•
1)
1)
1)
R-W Code
0-0
r00
1-2
r01
0-2
r02
0-2
r03
1-2
r05
1-2
r09
1-2
r10
0-2
r12
1-2
r13
1-2
r14
1-2
r15
1-2
r16
1-2
r17
0-2
r21
1-2
r53
1-2
r59
1-2
r61
1-2
r62
1-2
r63
1-2* r89
1-2
r98
DO6
AO1 AI1 AI2 AI3 AI4 AI5 AI6
•
Pe
•
Pe
•
Pe
•
Pe
•
Pe
•
Pe
•
Pe
•
Pe
•
•
1)
1)
Pe
Wiring diagram pages 10-12
1
2
3
4
5
6
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
AI7/
DI2 DI3
DI1
• • •
S2
S3
S4
S5
S6
• • •
S2
S3
S4
S5
S6
• • •
S2
S3
S4
S5
S6
• • •
S2
S3
S4
S5
S6
• • •
S2
S3
S4
S5
S6
• • •
S2
S3
S4
S5
S3B
• •
S2
S3
S4
S5
S3B
S5B
• •
S2
S3
S4
S5
S6
RH%
• • •
S2
S3
S4
S5
S6
Min. value Max. value
7
8
9
1
1
1 "r03"
"r02"
1
1
1 0.1 K
20 K
1
1
1 "r03"
50 °C
1
1
1 -50 °C
"r02"
1
1
1 0/°C
1/F
1
1
1 -10 K
10 K
1
1
1 -10 K
10 K
1
1
1 -1
1
1
1
1 -50 K
50 K
1
1
1 1
2
1
1
1 0 %
100 %
1
1
1 0 hrs
10 hrs
1
1
1 0 min.
30 min.
1
1
1 -50 °C
50 °C
1
-10 K
10 K
1
1 -10 K
10 K
1
1
1 0 %
100 %
1 0 K
50 K
1 0 min.
240 min.
1
1
1 0
5
1
1
1 -50 °C
50 °C
© Danfoss | DCS (vt) | 2019.09
SW = 2.0x
Factory
Actual
setting
setting
2
2
50
-50
0/°C
0
0
0
0
1
100
1
5
2
0
0
100
5
240
0
-50