Danfoss AK-CC55 User Manual page 30

Controller for appliance control
Hide thumbs Also See for AK-CC55:
Table of Contents

Advertisement

User Guide | Controller for appliance control, AK-CC55
Single Coil - continued
Access code 2 (partial access)
Replace the controller's factory settings with the
present settings
Input signal on DI3. Function: (high voltage input)
0=not used. 1=status on DI2. 2=door function with
alarm when open. 3=door alarm when open. 4=defrost
start (pulse-signal). 5=ext. main switch. 6=night
operation. 7=thermostat band changeover (activate
r21). 8=Not used. 9=Not used. 10=Appliance cleaning
(pulse signal). 11=forced cooling at hot gas defrost.
12=Open night cover. 13=Not used. 14=Refrigeration
stopped (forced closing). 15=case shutdown. 16=light.
20=Refrigerant alarm. 21= adaptive liquid control
when short-circuited.
Rail heat control
0=not used, 1=pulse control with timer function (o41
and o42), 2=pulse control with dew point function A
Dew point value where the rail heat is minimum
Dew point value where the rail heat is 100% on
Lowest permitted rail heat effect in %
Time delay from "open door" refrigeration is started
Fan operation at stopped cooling (forced closing):
0= Stopped (defrost allowed)
1= Running (defrost allowed)
2= Stopped (defrost not allowed)
3= Running (defrost not allowed)
Readout of temperature value shown in display 1
1= u56 air temperature
2= u36 product temperature
Light and night blinds defined:
0: Light is switched off and night blind is opened when
the main switch is off
1: Light and night blind is independent of main switch
Configuration of alarm relay:
The alarm relay will be activated by an alarm in one or
more of the following priorities.
Setting:
0 = The relay is not activated by alarms
1 = Only high priority alarms
2 = High priority and intermediate priority alarms
3 = High priority, intermediate priority and low priority
Max. opening time of night blinds after a manual
override with DI activation.
Stop time for fans while the night blinds roll down
Cycle time for rail heat at PWM on AO1
User defined refrigerant 3-digit Rfg. factor K1
User defined refrigerant 3-digit Rfg. factor K2
User defined refrigerant 3-digit Rfg. factor K3
Max. limitation of the superheat reference when
regulated with liquid-filled evaporator
Min. limitation of the superheat reference when
regulated with liquid-filled evaporator
Access code 1 (simple access)
Locking the display control. 0/Off=operation. 1/
On=locked
Configuration of relay output DO2: 0=not used, 1=fan,
2=fan Eco, 3=defrost, 4=rail heat, 5=alarm, 6=light,
7=night blinds, 8=compressor, 9=compressor 2,
10=heating element
30 | BC308437742037en-000101
R-W Code
1
2 3
4
2-2
o64
1
1
1
1
3-3* o67
1
1
1
1
1-2* o84
1
1
1
1
1-2
o85
1
1
1
1
1-2
o86
1
1
1
1
1-2
o87
1
1
1
1
1-2
o88
1
1
1
1
1-2
o89
1
1
1
1
1-2
o90
1
1
1
1
1-2
o97
1
1
1
1
1-2
o98
1
1
1
1-2
P41
1
1
1
1-2
P60
1-2
P65
1-2
P82
1
1
1
1
1-3* P83
1
1
1
1
1-3* P84
1
1
1
1
1-3* P85
1
1
1
1
1-2
P86
1
1
1
1
1-2
P87
1
1
1
1
1-1
P88
1
1
1
1
1-2
P89
1
1
1
1
1-3* q02
5
6 7
8
9
Min.
1
1
1
1
1 0
1
1
1
1
1 0/Off
1
1
1
1
1 0
1
1
1
1
1 0
1
1
1
1
1 -10°C
1
1
1
1
1 "o86"
1
1
1
1
1 0 %
1
1
1
1
1 0 min.
1
1
1
1
1 0
1
1
1
1
1 1
1
1
1
1
1 0
1
1
1
1 0
1 0 min.
1 0 sec
1
1
1
1
1 4 sec
1
1
1
1
1 -999
1
1
1
1
1 -999
1
1
1
1
1 -999
1
1
1
1
1 "P87"
1
1
1
1
1 0°C
1
1
1
1
1 0
1
1
1
1
1 0/Off
1 0
Max.
Fac.
Actual
999
0
1/On
0/Off
21
0
2
0
"o87"
8
50 °C
17
100 %
30
240 min.
30
3
1
2
1
1
0
3
2
60 min.
5
300 sec
0
60 sec
10
999
300
999
300
999
300
20°C
3
"P86"
1
999
0
1/On
0/Off
10
5
© Danfoss | DCS (vt) | 2019.09