User Guide | Controller for appliance control, AK-CC55
Readout of alarm air temp. Section B
Readout of display 2 value
Status of the relay for the Eco fan
Display of signal quality for the MODBUS communication
Status of the relay for the drain valve
Display of measured humidity in %
Status of the humidity relay
Display of rail heat effect via AO1 in %
DO1 - DO6 (Not shown in a display)
A relay output can be defined for the following functions. The function is indicated
by the number:
0=None, 1=AKV, 2=fan, 3=fan Eco, 4=defrost, 5=rail heat, 6=alarm, 7=lights,
8=night blind, 9=compressor, 10=compressor 2, 11=heat element, 12=drain valve,
13=suction valve, 14=hot gas valve, 15=defrost B, 16=humidity
AO1 (Not shown in a display)
The output can be defined for: 0=no function. 1=rail heat
Display of measured food temperature (defined in q39)
Display of measured defrost stop temperature (defined in d10)
Operating status. Section B. Please refer to the overview on page 62
Read the duration of ongoing defrost or duration of the last completed defrost.
Section B
Read the temperature at the S4B sensor
Thermostat temperature. Section B
Read ongoing cut-in time for the thermostat or the duration of the last completed
cut-in. Section B
Read the temperature at the S2B sensor
Read superheat. Section B
Read superheat reference. Section B
Opening degree of AKV valve. Section B
Operating status. Section C. Please refer to the overview on page 62
Read the duration of the ongoing defrost or the duration of the last completed
defrost. Section C
Read the temperature at the S4C sensor
Thermostat temperature. Section C
Read ongoing cut-in time for the thermostat or the duration of the last completed
cut-in. Section C
Read the temperature at the S2C sensor
Read superheat. Section B
Read superheat reference. Section C
Opening degree of AKV valve. Section C
Readout of alarm air temp. Section C
Display of measured defrost stop temperature (defined in d10). Section B
Display of measured defrost stop temperature (defined in d10). Section C
© Danfoss | DCS (vt) | 2019.09
U34
Alarm air B
U35
Display air2
U37
Fan Eco
U45
Comm. Status
U55
Drain valve
U57
RH level %
U58
RH relay
U59
RailheatPWM
U61
DO1 config
U62
DO2 config
U63
DO3 config
U64
DO4 config
U65
DO5 config
U66
DO6 config
U67
DO7 config
U69
AO1 config
U72
Food temp
U73
Def.StopTemp
U74
Ctrl. State B
U75
Def. Time B
U76
S4 temp B
Ther. Air B
U77
U78
TherRuntimeB
U79
S2 temp. B
U80
Superheat B
SH Ref B
U81
U82
AKV OD % B
Ctrl. State C
U83
U84
Def. Time C
U85
S4 temp C
U86
Ther. Air C
U87
TherRuntimeC
S2 temp. C
U88
U89
Superheat C
U90
SH Ref C
U91
AKV OD %
U92
Alarm air C
U93
Def.StopTemB
U94
Def.StopTemC