Juniper PTX1000 Hardware Manual page 88

Packet transport router
Hide thumbs Also See for PTX1000:
Table of Contents

Advertisement

Figure 34: Connecting a Right-Angle DC Power Cable to a DC Power Supply in a PTX1000
(CBL-JNP-PWR-DSUB3)
WARNING:
or drape where people could trip over them.
5. Using the slotted screwdriver, tighten the screws on the power cable connector to between 6 lb-in
(0.68 Nm) and 7 lb-in (0.79 Nm).
CAUTION:
screws on the DC power cable connector. Do not overtighten the screws. Applying
excessive torque damages the terminal block and the wiring tray. The absolute
maximum torque that may be applied to this screw is 10 lb-in (1.13 Nm).
6. Repeat Step
4
and Step
7. Close the input circuit breaker.
NOTE:
We recommend that the 48-VDC facility DC source be equipped with a circuit breaker
rated at 40 A (–48 VDC) minimum, or as required by local code.
Ensure that the power cables do not block access to device components
You must use an appropriate torque-controlled tool to tighten the
5
for each power supply that you are connecting to power.
88