Table 31: PTX1000 Chassis Alarm Messages (continued)
Component
Alarm Type
Temperature
Major (red)
sensors
Minor (yellow)
Routing Engine
Major (red)
Minor (yellow)
Management
Major (red)
Ethernet interface
RELATED DOCUMENTATION
CLI Message
sensor-location Temp Sensor Fail
sensor-location Temp Sensor Too Hot
sensor-location Temp Sensor Too
Warm
RE RE number /var partition is full
RE RE number /var partition usage is
high
Management Ethernet 1 Link Down
Recommended Action
Check the system log for the following
message and report it to customer
support:
Temp sensor sensor-number failed,
where sensor-number ranges from 1
through 10.
Check environmental conditions and
alarms on other devices. Ensure that
environmental factors (such as hot air
blowing around the equipment) do not
affect the temperature sensor. If the
condition persists, the device might
shut down.
For information only. Check
environmental conditions and alarms
on other devices. Ensure that
environmental factors (such as hot air
blowing around the equipment) do not
affect the temperature sensor.
Clean up the system file storage space
on the device. For more information,
see request system storage cleanup.
Clean up the system file storage space
on the device. For more information,
see request system storage cleanup.
Check whether a cable is connected
to the management Ethernet interface,
or whether the cable is defective.
Replace the cable, if required.
If the problem cannot be resolved,
open a support case.
118