Entrance Delay; Alarm Duration; Pgx And Pgy Output Functions; Recorded Message And Phone Number Editing In The User Mode - jablotron JA-65 MAESTRO Installation Manual

Hide thumbs Also See for JA-65 MAESTRO:
Table of Contents

Advertisement

11.4. Entrance delay

To change duration of the entrance delay enter: 21x (where x
represents time in seconds x10). The delay can be selected
from 10 to 90 seconds.
Example: To select entrance delay duration of 40 seconds, enter
214
Factory default setting: 30 seconds

11.5. Alarm duration

The alarm duration can be selected from 1 to 8 minutes (or 10
seconds or 15 minutes) entering 22x (where x represents time in
minutes, for x=0 the duration will be 10 seconds, for x=9 the
duration will be 15 minutes).
Example: to select an alarm duration of 5 minutes, enter 225
Factory default setting: 4 minutes

11.6. PgX and PgY output functions

The control panel outputs
PgX and PgY can have
different
functions,
depending on parameter x
in
the
corresponding
sequence:
2 3 x – determines
triggering of
PgX
2 4 x – determines
triggering of
PgY
where x
represents the following functions (non split
system):
0
Chime – triggered during the entrance delay (pre-
alarm output)
1
Fire – triggered by a fire alarm (by a smoke or a
gas detector)
2
Arm – activated when the control panel is armed
(complete & partial arming)
3
Panic – activated when a silent panic alarm is
triggered
4
Alarm – triggered by any audible alarm (except
panic alarm)
5
Door – activated for 5sec. after
entering (electric door lock opening)
6
Home – activated when the control panel is
partially armed (Home arming)
No AC – triggered by an AC power failure
Phone/F8 – output can be operated remotely by phone or
by SMS (if this feature is supported by installed
communicator) or locally from the keypad by F81
(ON) and F80 (OFF). If a code is requested to
operate the system
should be followed by a valid user code.
Example: the PgX will work as a Panic output when 233
is entered, PgY as Door output when 245 is entered.
Factory default setting: PgX=Chime, PgY=Arm
Note: the control panel also wirelessly transmits the PgX and
PgY signals. Wireless output modules UC-216 and UC-222 can
be used to receive the signals (see 11.12). The function of the
UC module output relays is determined by the 23x and 24x
setting.
Alarm system JA-65 MAESTRO
sequence: 2 1 x
sequence: 2 2 x
sequences: 2 3 x & 2 4 x
If the system is split:
x
23x (PgX) 24x (PgY)
0
Alarm A
Alarm A
1
Alarm B
Alarm B
2
Chime A
Chime A
3
Chime B
Chime B
4
Arm A
Arm B
5
Door A
Door B
6
Panic A
Panic B
7
FIRE
NoAC
8
Phone
Phone
then the F8x instruction
11.7. Recorded message and phone number editing in
the user mode
The User mode, which is accessible with F 0 "Master Code", is for
bypass setting, system testing and battery replacement. This
setting enables the user to change the voice message and
telephone numbers of the built in dialer. If the changes are
enabled, then programming sequences for number programming,
voice message recording and dialer testing are accessible in the
User mode. These settings have effect only when the control
panel has a 65X communicator module.
options:
2 5 1
changes enabled
2 5 0
changes disabled (no dialer programming in the
User mode)
Factory default setting: changes disabled

11.8. Radio signal jamming testing

When this function is enabled, the control panel will indicate
trouble if the working band is jammed for more than 30 seconds.
Jamming will trigger an alarm when the control panel is armed.
Do not enable this testing, if the control panel does not have a
65R radio module.
options:
2 6 1
testing enabled
2 6 0
testing disabled
Factory default setting: disabled
Note: in some locations the system can be repeatedly jammed
for some period of time (near radar, TV or radio station etc.). In
these cases the control panel can work without any problems
because all important data is repeated, but the jamming test
should not be enabled. The level of the signals and interference
can be observed using the Comlink software (see 14.)

11.9. Regular communication checking

The control panel will check communication regularly with all
enrolled items (detectors, keypads, siren etc.) when this function is
enabled. If communication is lost with any item, the control panel will
indicate the fault of this item (when armed reaction of the system
depends on setting 696x, see 11.28). Do not enable this checking, if
the control panel does not have the 65R radio module.
options:
2 7 1
checking enabled
(F3)
2 7 0
checking disabled
Factory default setting: checking disabled
Note: in some locations with a strong radio interference (near radar,
TV or radio station etc.) the communication can be jammed
periodically. The control panel can detect such a strong interference
as a temporary loss of communication with an item. Even in this
case, the system is usually able to work without any problems,
because all important data is repeated, but the communication
check should not be used.

11.10. Reset enabled

The factory default reset (see 13) can be disabled. This way no
unauthorized future programming of the control panel will be
possible.
options:
2 8 1
reset enabled
2 8 0
reset disabled
Factory default setting: reset enabled
- 10 -
sequence: 2 5 x
sequence: 2 6 x
sequence: 2 7 x
sequence: 2 8 x
MFM53003

Advertisement

Table of Contents
loading

Table of Contents