Exit / Entrance Delay; Alarm Duration; Pgx And Pgy Output Functions; Message And Numbers: Editing In The User Mode - jablotron JA60K Installation Manual

Table of Contents

Advertisement

7.2.3. Exit / Entrance delay

To change the duration of the exit and entrance delay (both of them) enter 21x (where x represents time in seconds x10).
The delay can be selected from 10 to 90 seconds.
Example: to select an Exit and Entrance delay duration of 20 seconds, enter 212
Factory default setting is 30 seconds

7.2.4. Alarm duration

The alarm duration can be selected from 1 to 9 minutes (or 10 seconds) entering 22x (where x represents time in min-
utes, for x=0 the duration will be 10 seconds).
Example: to select an alarm duration of 5 minutes, enter 225
Factory default setting is 4 minutes
7.2.5. PgX and PgY outputs function
The control panel outputs PgX and PgY can have different functions, depending on parameter x in the corresponding se-
quence:
2 3 x – determines triggering of PgX
2 4 x – determines triggering of PgY
where x represents the following functions:
0
Chime – triggered during the entrance delay (pre-alarm output)
1
Fire – triggered by a fire alarm (triggered by a smoke or a gas detector)
2
Arm – activated when the control panel is armed (complete & partial arming)
3
Panic – activated when a silent panic alarm is triggered
4
Alarm – triggered by any audible alarm (except panic alarm)
5
Door – activated for 5sec. after F 3 entering (electric door lock opening)
6
Home – activated when the control panel is partially armed (Home arming)
7
No AC – triggered by an AC power failure
Example: the PgX will work as a Panic output when 233 is entered, PgY as Door output when 245 is entered.
Factory default setting: PgX=Chime, PgY=Arm
Note: the control panel also wirelessly transmits the PgX and PgY signals. Wireless output modules UC216 and UC222
can be used to receive the signals (see 8.1.3.). The function of the UC module output relays is determined by the 23x and
24x setting.
7.2.6. User recorded message and phone numbers: editing in the user mode*sequence: 2 5 x
The User mode which is accessible with F 0 "Master Code" is for battery replacement and system testing. This setting
enables the user to change the voice message and telephone numbers of the built in dialer. If the changes are enabled,
than programming sequences 6=tel. numbers programming, 7=voice message recording and 8=dialer testing are acces-
sible in the User mode (see description bellow).
options:
2 5 1
2 5 0
Factory default setting: changes disabled

7.2.7. Radio signal jamming testing

When this function is enabled, the control panel will indicate trouble if the working band is jammed for more than 30 sec-
onds. Jamming will trigger an alarm when the control panel is armed..
options:
2 6 1
2 6 0
Factory default setting: disabled
Alarm system JA-60 "COMFORT"
changes enabled
changes disabled (no programming in the User mode)
testing enabled
testing disabled
-
11 -
sequence: 2 1 x
sequence: 2 2 x
sequences: 2 3 x & 2 4 x
sequence: 2 6 x