Pg Outputs Control Via; Blocking/ Disabling The System; Blocking Users; Remote Control - jablotron 100 User Manual

Hide thumbs Also See for 100:
Table of Contents

Advertisement

14
2. OPERATING THE JABLOTRON 100 SYSTEM
It's possible to set / unset the system using icons on the lower bar of the program or with the "Status"
buttons in the "Section" tab. If a keypad with at least one controllable segment is used in the system,
then it is possible to set/unset the system in J-Link using an on-screen virtual keypad (click on "Keypad"
in the main menu).
Warning: When the system is controlled via PC, it won't prevent setting with a triggered device.
Be careful when you control the system this way!

2.9 PG OUTPUTS CONTROL VIA...

Keypad segment
A PG output switches on by pressing a button on the right side of the segment and switches off
by pressing the button on the left side. If the output is confi gured as a pulse output, it's switched off
according to the preset time.
PG control may or may not be stored in the control panel's event memory. Confi guration is done by
a service technician.
Authorization is/isn't demanded based on the system confi guration.
User keypad authorization
It's possible to activate a PG output just by user authorization (entering a code or using an RIFD tag).
The PG output must be confi gured to activate from a designated keypad.

Remote control

By pressing an assigned button of a remote control. Two-way remote controls confi rm activation of PG
outputs with an LED indicator.
Dialling-in
Each telephone number stored in the system (one user can have one telephone number) can control
it just by dialling-in (i.e. without establishing a call). Dialling-in consists of dialling the phone number of
the SIM card used in the security system and hanging up before the system answers the call. By default,
the system will answer the call after the third ring (approximately 15 seconds).
SMS message
Sending an SMS can switch on/off a particular PG. Authorization is/isn't demanded based on the system
confi guration.
Example: CODE_CONFIGURED TEXT
MyJABLOTRON website
By clicking on ON/OFF in the Automation (PG) tab.
My JABLOTRON smartphone app
By tapping on ON/OFF in the Automation (PG) tab.

3. BLOCKING/ DISABLING THE SYSTEM

3.1 BLOCKING USERS

Any user can be temporarily blocked (e.g. when a user loses a card/tag or his access code is revealed).
When user's access is blocked their ID code or card/tag will no longer be accepted by the system.
The users will also not receive any text message alerts or voice reports to their phone.