12.4. Alarm duration

The alarm duration can be selected from 1 to 8 minutes (or 10 seconds or 15 minutes) entering 22x (where x represents
time in minutes, for x=0 the duration will be 10 seconds, for x=9 the duration will be 15 minutes).
Example: to select an alarm duration of 5 minutes, enter 225
Factory default setting is 4 minutes

12.5. PgX and PgY output functions

The control panel outputs PgX and PgY can have different functions, depending on parameter x in the corresponding
sequence:
2 3 x – determines triggering of PgX
2 4 x – determines triggering of PgY
where x represents the following functions (non split system):
0 Chime – triggered during the entrance delay (pre-alarm output)
1 Fire – triggered by a fire alarm (by a smoke or a gas detector)
2 Arm – activated when the control panel is armed (complete & partial arming)
3 Panic – activated when a silent panic alarm is triggered
4 Alarm – triggered by any audible alarm (except panic alarm)
5 Door – activated for 5sec. after
6 Home – activated when the control panel is partially armed (Home arming)
7 No AC – triggered by an AC power failure
Example: the PgX will work as a Panic output when 233 is entered, PgY as Door output when 245 is entered.
Factory default setting: PgX=Chime, PgY=Arm
Note: the control panel also wirelessly transmits the PgX and PgY signals. Wireless output modules UC-216 and UC-222 can be used
to receive the signals (see 25.1.). The function of the UC module output relays is determined by the 23x and 24x setting.

12.6. Recorded message and phone number editing in the user mode

The User mode, which is accessible with F 0 "Master Code", is for bypass setting, system testing and battery
replacement. This setting enables the user to change the voice message and telephone numbers of the built in dialer. If
the changes are enabled, then programming sequences for number programming, voice message recording and dialer
testing are accessible in the User mode. These settings have effect only when the control panel has a 65X communicator
module.
options:
2 5 1
2 5 0
Factory default setting: changes disabled

12.7. Radio signal jamming testing

When this function is enabled, the control panel will indicate trouble if the working band is jammed for more than 30
seconds. Jamming will trigger an alarm when the control panel is armed. Do not enable this testing, if the control panel
does not have a 65R radio module.
options:
2 6 1
2 6 0
Factory default setting: disabled
Note: in some locations the system can be repeatedly jammed for some period of time (near radar, TV or radio station etc.). In these cases the control
panel can work without any problems because all important data is repeated, but the jamming test should not be enabled. The level of the signals and
interference can be observed using the Comlink software (see 19.)

12.8. Regular communication checking

The control panel will check communication regularly with all enrolled items (detectors, keypads, siren etc.) when this
function is enabled. If communication is lost with any item, the control panel will indicate the fault of this item (when armed
it will also trigger an alarm). Do not enable this checking, if the control panel does not have the 65R radio module.
Alarm system JA-65 MAESTRO
(F3) entering (electric door lock opening)
changes enabled
changes disabled (no dialer programming in the User mode)
testing enabled
testing disabled
- 11 -
sequence: 2 2 x
sequences: 2 3 x & 2 4 x
If the system is split:
23x (PgX) 24x (PgY)
x
0
Alarm A
Alarm A
1
Alarm B
Alarm B
2
Chime A
Chime A
3
Chime B
Chime B
4
Arm A
Arm B
5
Door A
Door B
6
Panic A
Panic B
7
FIRE
NoAC
sequence: 2 5 x
sequence: 2 6 x
sequence: 2 7 x