■Default setting

Function (Main display)
(Main display)
[rEF ] Select display units
[F 0]
[Unit] Units selection function
[NorP] Select NPN/PNP
[oUt1] Select output mode
[1ot ] Select switch mode
[P_1 ] Select input switch operation
[F 1]
[H_1 ] Setting of Hysteresis
[dt1 ] Delay time setting
[CoL ] Select display colour
[oUt2] Select output mode
[2ot ] Select switch mode
[P_2 ] Select input switch operation
[F 2]
[H_2 ] Setting of Hysteresis
[dt2 ] Delay time setting
[CoL ] Select display colour
[F 3]
[FiL ] Select digital filter
[FUnC] Select FUNC
[F 5]
(switching analogue output/external input)
[F10]
[SUb ] Select sub display (Line name setting
[F13]
[rEv ] Select Reverse display
[F14]
[CUt ] Select Zero cut-off setting
[F30]
[SAvE] Accumulated value hold
[F80]
[diSP] Display OFF mode
[F81]
[Pin ] Security code
[F90]
[ALL ] Setting of all functions
[F96]
[S_in] Check of input signal
[F98]
[tESt] Setting of output check
[F99]
[ini ] Reset to the default settings
1: Setting is only possible for models with the units selection function.
2: [F 2] The OUT2 setting can be set on the product screen, but since there is no OUT2 switch output function as an output
specification, it is not possible to output the ON/OFF signal to an external device.
3: When the 1 switch output type (output specification symbol is L) is used, [F5] is displayed as [---] and cannot be set.
1 to 5 V or 0 to 10 V can be selected when the analogue voltage output type is used.
Analogue output free range function can be selected.
4: When Line name is selected, a suitable line name can be input.
(Left sub display)
1
4
-32-
Default Settings
(Right sub display)
[ Std] Standard condition
[
L] L/min
[ PnP] PNP output
[ HYS] Hysteresis mode
[ 1_P] Normal output
[1500] 1500 L/min (PF3A703H)
[3000] 3000 L/min (PF3A706H)
[6000] 6000 L/min (PF3A712H)
[ 150] 150 L/min (PF3A703H)
[ 300] 300 L/min (PF3A706H)
[ 600] 600 L/min (PF3A712H)
[0.00] 0.00 s
[1SoG] Green when ON
Red when OFF (OUT1)
[ HYS] Hysteresis mode
[ 2_P] Normal output
[1500] 1500 L/min (PF3A703H)
[3000] 3000 L/min (PF3A706H)
[6000] 6000 L/min (PF3A712H)
[ 150] 150 L/min (PF3A703H)
[ 300] 300 L/min (PF3A706H)
[ 600] 600 L/min (PF3A712H)
[0.00] 0.00 s
[1SoG] Green when ON
Red when OFF (OUT1)
[ 1.0] 1 second
[AoUt] Analogue output
3
[ dEF] Default setting
)
[ oFF] Reverse display OFF
[ 1.0] 1%F.S. cut
[ oFF] Not stored
[ on] Display ON
[ oFF] Not used
[ oFF] Not used
[ - - - ] No input signal
[
n] Normal output
[ oFF] Not used
Applicable
Page
Page
33
Page
35
2
Page
44
Page
45
Page
48
Page
50
Page
51
Page
55
Page
56
Page
57
Page
59
Page
61
Page
62
Page
65
No.PF※※-OMX0002

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pf3a706h-lPf3a712h-lPf3a703hPf3a706hPf3a712h

Table of Contents