SMC Networks PF3A703H-L Operation Manual page 81

Digital flow switch
Hide thumbs Also See for PF3A703H-L:
Table of Contents

Advertisement

●Product individual parameters (continued)
Index
Access
Sub
1
index
dec
hex
1320 0x0528
0
R/W
1330 0x0532
0
R/W
1520 0x05F0
0
R/W
1530 0x05FA
0
R/W
AC
1600 0x0640
0
R/W
(Setting of the accumulated
flow output direction)
FiL
1800 0x0708
0
R/W
(Digital filter)
Sub
1
R/W
(Setting of lower level
display)
2000 0x07D0
dEF
2
R/W
[Selection of display items
during dEF setting]
rEv
2020 0x07E4
0
R/W
(Reserved Display setting)
Cut
2030 0x07EE
0
R/W
(Zero cut-off setting)
in
2040 0x07F8
0
R/W
(External input setting)
AoUt
2100 0x0834
0
R/W
(Setting of analogue output)
FrEE
1
R/W
(Setting of free range mode)
2110 0x083E
F_H
2
R/W
(Set value of free range)
SAVE
2200 0x0898
0
R/W
(Accumulated flow value
hold setting)
diSP
2400 0x0960
0
R/W
(Display OFF setting)
Data
Initial
Parameter
type
value
2
PLS1_L
U8
0
3
U8
0
PLS1_Ft
PLS1_L
U8
0
3
U8
0
PLS1_Ft
U8
0
U8
0
U8
0
U8
20
U8
0
U8
0
U8
0
U8
0
U8
0
S16
4000
U8
0
U8
0
-80-
Data
4
storage
Set value
3
0: 100 (L/pulse)
Y
1: 1000 (L/pulse)
3000/6000 L range
0: 1 (L/pulse)
1: 10 (L/pulse)
Y
12000 L range
0: 10 (L/pulse)
1: 100 (L/pulse)
0: 100 (L/pulse)
Y
1: 1000 (L/pulse)
3000/6000 L range
0: 1 (L/pulse)
1: 10 (L/pulse)
Y
12000 L range
0: 10 (L/pulse)
1: 100 (L/pulse)
0: Add (Addition)
1: dEC1
Y
(Subtraction OUT1)
2: dEC2
(Subtraction OUT2)
0: 1.0 sec
Y
1: 2.0 sec
2: 5.0 sec
0: dEF (Default)
Y
1: LinE (Line name)
2: oFF (Display is OFF)
Refer to "Selection of
Y
display items" when dEF
is set". (Page 83)
0: oFF (Normal display)
Y
1: on (Reversed display)
Setting range
Y
0x0000 to 0x000A
(0 to 10)
0: rAC
(Reset accumulation)
Y
1: rPb
(Reset peak/bottom)
0: 1 to 5 V
Y
1:0 to 10 V
0: oFF (Unused)
Y
1: on (Used)
Setting range
Y
0x0190 to 0x1068
(400 to 4200)
0: oFF (Not held)
Y
1: 2.0 min
2: 5.0 min
0: on
Y
1: oFF
Remarks
Accumulated pulse converted value
setting
Setting of the accumulated flow
output direction
Set digital filter
Setting of the lower level display
[Setting of display items of lower
display during dEF setting]
Reserved Display setting
1.0% increments
External input setting
Setting of analogue output
(Voltage output type only)
Setting of free range mode
Set value of free range
Rated value 10% to 105%
No.PF※※-OMX0002

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pf3a706h-lPf3a712h-lPf3a703hPf3a706hPf3a712h

Table of Contents