SMC Networks PF3A703H-L Operation Manual page 79

Digital flow switch
Hide thumbs Also See for PF3A703H-L:
Table of Contents

Advertisement

●Product individual parameters
Index
Sub
Access
1
index
dec
hex
Unit
1000 0x03E8
0
R/W
(Selection of display unit)
CoL
1010 0x03F2
0
R/W
(Selection of display colour)
NorP
1020 0x03FC
0
R/W
(Selection of switch output
PNP/NPN)
1030 0x0406
0
R/W
Change by FUNC
1070 0x042E
0
R/W
Reference condition
1
R/W
1210 0x04BA
2
R/W
1
R/W
2
R/W
3
R/W
1220 0x04C4
4
R/W
5
R/W
6
R/W
Data
Initial
Parameter
type
value
2
U8
0
U8
2
U8
1
U8
0
U8
0
oUt1
(Selection of output
U8
0
mode)
1ot
(Selection of output
U8
0
type)
P_1 (n_1)
S16
2000
(Selection of output
set value)
H_1
U16
200
(Setting of OUT1
hysteresis)
P1L (n1L)
S16
1200
(Lower limit of
window comparator)
P1H (n1H)
S16
2400
(Upper limit of
window comparator)
WH1
U16
400
(Window comparator
hysteresis)
dt1
U16
0
(Delay time)
-78-
Data
4
storage
Set value
3
0: L/min (L)
Y
3
1: cfm (ft
)
0: rEd (Constantly red)
1: Grn (Constantly green)
2: 1SoG
(OUT1 turns green at ON)
3: 1Sor
Y
(OUT1 turns red at ON)
4: 2SoG
(OUT2 turns green at ON)
5: 2Sor
(OUT2 turns red at ON)
0: NPN
Y
1: PNP
0: Aout (Analogue output)
Y
1: in (Exterior input)
0: std
(Standard condition)
Y
1: nor
(Normal condition)
0: HYS
(Hysteresis)
1: Wind
(Window comparator)
2: AC
Y
(Accumulated output)
3: PLS
(Accumulated pulse)
4: Err (Error output)
5: oFF (Output OFF)
0: 1_P (Normal output)
Y
1: 1_n (Reverse output)
Setting range
Refer to "Settable
Y
range list".
(Page 82)
Setting range
Refer to "Settable
Y
range list".
(Page 82)
Setting range
Refer to "Settable
Y
range list".
(Page 82)
Setting range
Refer to "Settable
Y
range list".
(Page 82)
Setting range
Refer to "Settable
Y
range list".
(Page 82)
Settable values
Y
0x0000 to 0x1770
(0 to 6000)
Remarks
When the unit selection function is
not included,
a read/write to an un-selectable item
is rejected.
Setting of display colour
Setting the switch output
FUNC terminal function setting
Setting of OUT1 output normal and
reserved output
Setting of OUT1 output set value
(Hysteresis)
Setting of OUT1 hysteresis
(Hysteresis)
Setting of OUT1 output set value
(Lower limit of window comparator)
Setting of OUT1 output set value
(Upper limit of window comparator)
Setting of OUT1 hysteresis
(Window comparator)
Setting of OUT1 delay time
10 ms increment
No.PF※※-OMX0002