Other Settings - SMC Networks PF3A703H-L Operation Manual

Digital flow switch
Hide thumbs Also See for PF3A703H-L:
Table of Contents

Advertisement

Other Settings

●Reset operation
The Accumulated Flow, Peak Value and Bottom Value can be reset.
To reset the accumulated value, press the ▼ and S buttons for 1 second or longer.
●Snap shot function
The current flow rate value can be stored to the switch output ON/OFF set point.
When the items on the Sub display (left) are selected in either 3 step setting mode, Simple setting mode or
Setting of each function mode, by pressing the ▲ and ▼ buttons simultaneously for 1 second or longer, the
value of the sub display (right) will show "----", and the values corresponding to the current flow rate are
automatically displayed.
Output mode
Hysteresis mode
Window comparator mode
•OUT1 set value
The value is set to the same value as the display value (current flow rate value).
(There is a range which cannot be set to the current flow rate depending on the hysteresis difference. In
that case, the value is set to the closest value.)
•Hysteresis
The hysteresis is calculated from the equation below and set.
Normal output: (OUT set value)-(current flow rate value)
Reverse output: (current flow rate value)-(OUT set value)
If the calculation result becomes 0 or less, [Err] is displayed on the sub display and the set value is not
changed.
Afterwards, it is possible to adjust the value by pressing ▲ or ▼ button.
●Change of the accumulated output
The accumulated flow display style can be changed temporarily while the sub display is assigned for the
accumulated flow display.
Power value is displayed
▼ (1 second)
Displayed in turn
: If the accumulated value does not reach the upper digits (more than 7 digits), only the lower digits are displayed.
: If a button operation is not performed for 30 seconds during the alternating display, the display will flash.
Configurable items
OUT set value
Hysteresis
OUT set value
Hysteresis
Assign the sub display for the accumulated value in measurement mode.
The normal accumulated display consists of the mantissa part (maximum
6 digits) and [Power value display] indicated by the index part displayed
9
6
3
by ×10
or ×10
or ×10
.
The upper digits and lower digits are displayed in turn by pressing the
▼ button during [Power value display] for 1 second. [Alternating display]
-66-
Sub display (left)
P_1 (n_1), P_2 (n_2)
H_1, H_2
P1L (n1L), P1H (n1H)
P2L (n2L), P2H (n2H)
WH1, WH2
Snap shot function
×
No.PF※※-OMX0002